5/20
In table 10, 4000+108 indicates that customers can choose how many channels to collect
temperature according to their needs and choose a 108 acquisition module with 8 channels as a
unit in the case of a host. If you need 80 channels, you can choose a 64 way host and 2 108
acquisition modules.
Technical parameter
:
Model
JK4000
Input type
Thermocouple: J/K/T/E/S/N/B type PT100
Measuring range
Measurement accuracy: 0
~
1000
℃
: ±(reading value×0.5%+1)
℃
,
-100
~
0
℃
:±(reading value×0.5%+2)
℃
;
Number of channels
8~64 channels can be expanded to 128 channels
Display
4.3 inch TFT color screen
Display resolution
0.1
℃
U disk storage
Yes
Scan speed
100ms/channel
Internal storage
No
Curve drawing
Yes
Communication
interface
RS232 port or USB port
Supporting software
2015 version V1.3 software
Alarm mode
One public alarm (relay output) (optional)
Voltage output
Internal independent power supply output
Anti-dry winding
Anti-high frequency interference
Single screen display
32 channels
Temperature correction Yes
Other functions
Clock function Calendar function
Terminal type
M3 screw type
Allowable
environmental
conditions
1. Power supply: AC 220V±10%, 50Hz±2%;
2. Use environment: working temperature: -20-70
℃
, relative humidity:
20%-90%;
Accessories
Standard configuration: K-type thermocouple (-50
℃
to 200
℃
) 8 pieces
(2 meters/piece), data acquisition software
Dimensions
Length×Width×Height: 36cm×26cm×16cm Overall weight: about 5kg