2.2.2 Environment Requirement

Ite m

Requirement

M ach in e   h all

spac e

W hen user insta ll mach ine frame a rray in  on e mac hine ha ll, the

d ista n ce   b etw een   2   row   o f  m ac h in e   fra m es  sh ou ld   b e  1 .2 ~1 .5m

an d   th e  d istan ce   to   w all  sh o u ld   be   no   less   th an   0 .8 m

M ach in e   h a ll   f lo o r

Electric Isolation, Dust Free

Volume resistivity of ground anti-static material:1(107~1(1010(

Grounding

current limiting resistance: 1M(

Floor bearing should be greater than 450Kg/m2

Environment

temperature

5~40(C sustainable

0~45(C short time

installing air-conditioning is recommended

Relative temperature

20%~80% sustainable   10%~90% short time

Pressure

86~105KPa

Door & window

Installing rubber strip for sealing door-gaps and dual level glasses for

window

Wall

It can be covered with wallpaper, or brightness less paint.

Fire protection

Fire alarm system and extinguisher

Power

Requiring device power, air-conditioning power and lighting power are

independent to each other. Device power requires AC power 220V

50Hz,50W Please carefully check before running.

2.2.3 Grounding Requirement

All function modules’ good grounding designs are the base of reliability and

stability of device. Also, they are the most important guarantee of lightning

arresting and interference rejection. Therefore, system must follow this rule.

Coaxial cable’s outer conductor and isolation layer should keep sound electric

Summary of Contents for INEN-6102

Page 1: ...JXDH 6102 Multiplexer User Manual V2 0 ChengDu Jiexun Electronics Co Ltd ...

Page 2: ...chronal multiplex 8 route input code streams and support ASI interface The code rate of input code stream is maximally up to 270Mbps while code rate of four separate outputs code stream is maximally up to 155Mbps Through auxiliary data input channel Its dimension is standard 1U case By watching the LCD display on the front panel user can finish the setting of auto running of this device 1 2 Featur...

Page 3: ... MPEG2 program delay less than 100 s PID filtration PID redefine function User can delete add revise program even the program name PID or serials No easily Chinese and English LCD display Ethernet interface10 100M long distance control multiplexer via PC Have the function of parameter memory Have the function of PSI auto built High reliability design stable in running Alarm display Support network...

Page 4: ...ion 44mmx482mmx410mm Temperature 0 45 Operating 20 80 Storage Miscellaneous Power 110 220VAC 10 50Hz 2 5W 1 4 Principle Chart 1 5 Appearance and Description Front Panel Illustration Ethernet module PS232 4 85 Controlling module LCD Keyboard PID filtrate mapped CH analyse select 8 input TS Input module TS adjusting controlling Output module multiplexing PID filtrate mapped CH analyse select TS adju...

Page 5: ...tration 1 8 ASI Input CH 2 Output CH1 3 Output CH2 4 RS232 5 RJ45 6 AC Power Socket 7 Grounding 1 LCD Display Interface 2 Power Indicator 3 Alarm Indicator 4 Input CH lock indicator 5 Up Down Left Right Arrow 6 Enter key 7 Menu Key RS232 RJ45 0 1 AC110 220V 50 60Hz 4 5 6 7 ASI IN 1 2 3 4 5 6 7 8 1 ASI OUT CH1 CH2 2 3 ...

Page 6: ...contact local dealer 2 2 Installation Preparation When users install device please follow the below steps The details of installation will be described at the rest part of this chapter Users can also refer rear panel chart during the installation The main content of this chapter including Checking the possible device missing or damage during the transportation Preparing relevant environment for in...

Page 7: ...tioning is recommended Relative temperature 20 80 sustainable 10 90 short time Pressure 86 105KPa Door window Installing rubber strip for sealing door gaps and dual level glasses for window Wall It can be covered with wallpaper or brightness less paint Fire protection Fire alarm system and extinguisher Power Requiring device power air conditioning power and lighting power are independent to each o...

Page 8: ...e machine frames should connect to protective copper strip The grounding wire should be as short as possible and avoid circling The section of the conjunction between grounding wire and grounding strip should be equal or greater than 25mm2 2 2 5 Device Grounding Connecting the device s grounding rod to frame s grounding strip with copper wire 2 3 Wire s Connection The power supply outlet is locate...

Page 9: ...ion User can find ASI IN1 IN8 input port on the Equipment according to connector mark described in the rear panel illustration and then connecting the Q9 coaxial cable one end to the ASI IN1 8 and the other end to the Encoder s or other equipment ASI output port 2 4 2 ASI Output Port Connection User can find ASI output port on the Equipment according to connector mark described in the rear panel i...

Page 10: ...t Equipment supply perfect Chinese and English menu for user select detail operations go as follows Front Panel Keyboard Function Description ENTER Activating and edit the parameters which needs modify or confirming the change after modification and turn over UP DOWN LEFT RIGHT Turn over Edit parameter MENU Lock Cancel Save Show current station 3 1 Main page Common station 3 2 Press ENTER to main ...

Page 11: ...f want to edit the TS of other ports select the related port will be ok 3 5 Output Rate When user select this setting the system will show as follows 3 6 Trans Stream ID When user select this setting the system will show as follows 1 1 Port 01 Setting 1 2 Port 02 Setting 1 3 Port 03 Setting 1 4 Port 04 Setting 1 5 Port 05 Setting 1 6 Port 06 Setting 1 7 Port 07 Setting 1 8 Port 08 Setting 1 9 Outp...

Page 12: ... select this setting the system will show as follows 3 9 Mux Number When user select this setting the system will show as follows 3 10 Output CH2 Setting The same as the setting of CH1 3 11 Program search When user select this setting the system will show as follows 1 10 Trans Stream_ID 0x0000 1 11 Original_network_ID 0x0000 1 12Yes Enter No Menu 3 1 Auto All Search 3 2 Port Search 1 13 Output 01 ...

Page 13: ...w as follows 3 13 Network Setting When user select this setting the system will show as follows 3 14 Factory config When user select this setting the system will show as follows Press Enter Renew Press Menu Exit 4 1 Network Setting 4 2 Factory config 4 3 Version Number IPAddress 101 101 101 100 Subnet Mask 255 255 255 000 GateWay 101 101 101 004 MAC Address 602020070505 ...

Page 14: ...w as follows 3 16 Language select When user select this setting the system will show as follows Press UP DOWN to select language the direct the selected one Default is Chinese version 3 17 Alarm Information When user select this setting the system will show as follows Finish all the setting the multiplexer can operate normally Hardware V1 0 Software V1 0 English No Alarm ...

Reviews: