conducting with the metal housing of device.
Grounding conductor must adopt copper conductor in order to reduce high
frequency impedance, and the grounding wire must be as thick and short as
possible.
The 2 terminals of grounding wire must make sure for well electric conducting,
and process for antirust.
It is prohibited that users use other devices as part of grounding wire’s electric
circuit
The section of the conjunction between grounding wire and device’s frame
should be equal or greater than 25mm2
2.2.4 Frame Grounding
All the machine frames should connect to protective copper strip. The
grounding wire should be as short as possible and avoid circling. The section of
the conjunction between grounding wire and grounding strip should be equal or
greater than 25mm2
2.2.5 Device Grounding
Connecting the device’s grounding rod to frame’s grounding strip with
copper wire.
2.3 Wire’s Connection
The power supply outlet is located at the left of rear panel, and the
power switch is just above it. The protective grounding wire connective
screw is located at the down-left side of power supply outlet
Connecting Power Cord
User can insert one end into power supply outlet, while insert the
other end to AC power.
Connecting Grounding Wire
When the device solely connects to protective ground, it should
adopt independent way, say, share the same ground with other devices.