JX2-IO16
6.9 System Bus
Jetter AG
53
6.9.2
Ordering Information
The system bus cable can be purchased from Jetter AG in various lengths. For more
information refer to chapter 2.3 "Ordering Information", page 20.
Note!
On the BUS OUT side of the system bus cable pins 3 and 5 have to be bridged.
For information refer to the table below.
System bus cable of cable confection # 530
Shield
BUS-OUT
X19
Connect shield with the greatest
possible surface area!
Use metallized housing only!
BUS-IN
X18
Pin
Signal
Pin
1
CMODE0
1
2
CL
2
3
GND
3
4
CMODE1
4
5
TERM (not connected)
5
6
Unassigned
6
7
CH
7
8
Unassigned
8
9
Do not connect