Appendix A: Overview - Outputs
The JX2-CNT1 module provides 8 virtual outputs enabling parameterization via
controller. A reset will clear all outputs.
Output
Number
Name
1) Default value
2) Cross reference
Single-channel counter
xx05
Counting Direction
1) Counting up
2) Page 59
0 = counting up
1 = counting down
Dual-channel c SSI encoder
xx03
Output of Master Position
1) Output of master position disabled
2) Page 87
0 = output of master position disabled
1 = output of master position on the system bus enabled
xx04
Encoder Selection
1) Dual-channel counter enabled
2) Page 75, Page 61
0 = dual-channel counter enabled
1 = SSI encoder enabled
Dual-Channel Counter
xx01
Signal Activation
1) STR enabled / REF disabled
2) Page 64
0 = STR enabled / REF disabled
1 = STR disabled / REF enabled
STR -> strobe function; REF -> reference function
(When this bit is set to 1, bit 3 in register 3xx3 "Status / Controller"
is reset automatically)
xx02
Counter Type
1) Dual-channel counter
2) Page 62
0 = dual-channel counter
1 = single-channel counter
SSI Encoder
xx06
Signal Coding
1) Gray code
2) Page 75
0 = Gray code
1 = binary code
xx07
Activation of Parity Check
1) Parity check disabled
2) Page 75
0 = parity check disabled
1 = parity check enabled
Summary of Contents for JetWeb JX2-CNT1
Page 10: ...Table of Contents JetWeb 10 Jetter AG ...
Page 18: ...1 Safety Instructions JetWeb 18 Jetter AG ...
Page 26: ...JetWeb 26 Jetter AG ...
Page 58: ...8 2 Firmware Version JetWeb 58 Jetter AG ...
Page 60: ...JetWeb 60 Jetter AG ...
Page 74: ...11 1 Reading in SSI data JetWeb 74 Jetter AG Fig 18 Examples Reading in Different SSI Formats ...
Page 82: ...12 1 Sample Program JetWeb 80 Jetter AG ...
Page 90: ...13 2 Mode 2 Operation along with JM 2xx JetWeb 94 Jetter AG ...
Page 91: ...JX2 CNT1 Appendices Jetter AG 95 Appendix ...
Page 92: ...Appendices JetWeb 96 Jetter AG ...
Page 95: ...JX2 CNT1 Appendices Jetter AG 99 ...