JX2-CNT1
10 Dual-Channel Counter
Jetter AG
65
Fig. 14: Signal waveform for referencing
10.4.2 Setting the Reference Offset
The count value of the dual-channel counter (register 3xx0) is zeroed using the
reference function. This way, the reference position is set to position 0 (refer to
“Setting the Reference Position" on page 64). Register 3xx1 "Dual-channel counter
- Offset" can be used to define any position as reference position (refer to “Reference
Offset" on page 66). In this connection, the previously determined reference position
of the mechanical system is maintained.