10.5 Reference Offset
JetWeb
66
Jetter AG
10.5
Reference Offset
The offset in register 3xx1 "Dual-channel counter - Offset" can be used to shift the
count value in register 3xx0 into positive or negative direction. This way, the
reference position is shifted accordingly. In doing so, the reference position of the
mechanical system remains unchanged.
The reference position offset has the following effect on register 3xx0 "Count value":
Example
The count value of the dual-channel counter is zeroed using the reference function
(register 3xx0 = 0). Via offset register 3xx1 the reference position is to be set to
10,000 increments.
– The user enters 10,000 into register 3xx1.
– The count value is set to 10,000 increments, or to a value around 10,000 if the
incremental encoder has moved during this process or is between 2 PPR counts
and is permanently oscillating.
Status bit 12 = 0
Register 3xx1: Dual-channel counter - offset
Function
Description
Read
Actual reference position offset of the dual-channel
counter
Write
New reference position offset of the dual-channel
counter
Value range
- 8.388.608 ... + 8,388,607 [increments]
Value following reset
0
R3xx0 (count) = internal count + R3xx1 (reference position offset)
Summary of Contents for JetWeb JX2-CNT1
Page 10: ...Table of Contents JetWeb 10 Jetter AG ...
Page 18: ...1 Safety Instructions JetWeb 18 Jetter AG ...
Page 26: ...JetWeb 26 Jetter AG ...
Page 58: ...8 2 Firmware Version JetWeb 58 Jetter AG ...
Page 60: ...JetWeb 60 Jetter AG ...
Page 74: ...11 1 Reading in SSI data JetWeb 74 Jetter AG Fig 18 Examples Reading in Different SSI Formats ...
Page 82: ...12 1 Sample Program JetWeb 80 Jetter AG ...
Page 90: ...13 2 Mode 2 Operation along with JM 2xx JetWeb 94 Jetter AG ...
Page 91: ...JX2 CNT1 Appendices Jetter AG 95 Appendix ...
Page 92: ...Appendices JetWeb 96 Jetter AG ...
Page 95: ...JX2 CNT1 Appendices Jetter AG 99 ...