JETI model SPIN 11 Manual Download Page 9

 

 

Timing Monitor

Measure or 

Setting

Auto Set

Acro Inrunner

Acro Outrunner

Glider Inrunner

Glider Outrunner

Heli Constant 

RPM

Heli constant 

RPM

3D

If  activated,  it  announces  5s  after  controller  activation  without  turning  the  motor  by 

means of beeps the actual timing condition as shown by the following table:

0-7°(single tones), 8-18°(double tones), 19-23°(triple tones), 24-30°(quadruple tones)

We apply this mode for putting the controller into operation in 

a fast and simple way for instance after loosing track during 

setting. The setting content is practically the same as setting 

with the help of R/C equipment. Confirmation of the setting is 

carried out by means of the push-button  P.

D

D

D

D

D

D

D

D

Remark 1:

  

Extending the battery cables.

As a matter of principle only cables from the battery to the controller can be extended. If the extension is larger than 

20 cm it is unavoidable to connect between the cables a low impedance electrolytic capacitor of a capacity 100-300 µF. 

These capacitors must be inserted between every cable section longer than 25-30 cm.

Remark 2:

  

Multi motor models

We recommend to use the same controller type for each motor. In case of SPIN controllers switch on only one BEC. 

The switches of the other controllers remain in the “SWITCHED OFF” position.

When using controllers with BEC it is generally necessary to use only one common flight battery. If we want to to utilize  

2 and more batteries these must be connected in parallel.

9

return to main

menu

TIP:

If you do not know the pole number of your motor please contact the manufacturer.

If you own a revolution counter and know the gear ratio of your gear box (direct 1:1) you will be able to find the pole 

number as follows.

Switch on the motor and with the help of the revolution counter measure the maximum propeller (rotor) rpm. Connect 

the JETI Box and go in the menu MEASUREMENT to the maximum propeller RPM display (Max. Prop RPM). If the 

shown value does not correspond with your measured value check the gear ratio setting (Gear) and change the pole 

number inputs until your measured RPM will be identical with the value in the JETI Box display (Max. Prop RPM). As a 

result you will obtain the pole number of your motor (Motor Pole No.)

Summary of Contents for SPIN 11

Page 1: ...Controllers SPIN 1...

Page 2: ...ation see to it that the connectors stay clean and the plug in force remains high If this force decreases replace the connectors immediately We recommend replacement of connectors after 1 2 flight sea...

Page 3: ...is reached groups of three tones mode 3 Glider inrunner this mode is appointed to gliders driven by motors of classic conception inrunner brake activated timung 0 gradual switching off when 68 of the...

Page 4: ...red Instantaneous battery voltage Value at which the motor has been switched off or its power throttled down as well as the time at which this value occurred Setting with the help of the JETI Box This...

Page 5: ...registers the max rpm of the propeller in the course of operation and the time at which these rpm have been achieved If parameters have been exceeded voltage U temperatures T com mutation C and curren...

Page 6: ...ons L P Speed of braking time between the begin of braking and attainment of the preset final braking effekt The time is set by push buttons L P Setting for model helicopters with speed regulation Set...

Page 7: ...5 and more seconds Enter by means of the push buttons L P the type of flight battery For NiCd NiMh cells the min voltage per cell is entered by push buttons L P For LiIon LiPol batteries we can either...

Page 8: ...lue is exceeded no extension of the regulation range occurs Regulation curve Logarithmical a logarithmic course of rpm with the throttle stick displacement linear power course with the throttle stick...

Page 9: ...erted between every cable section longer than 25 30 cm Remark 2 Multi motor models We recommend to use the same controller type for each motor In case of SPIN controllers switch on only one BEC The sw...

Page 10: ...inrunner Off Voltage Set Cut Off LiIo Po cut off V Per Cell Throttle Curve Auto Inc End Point End Point Initial Point Auto Temperature Protection Brake Manual Setting Number of cells Battery Type LiIo...

Reviews: