Min.
Temperature
Actual
Temperature
Max.
Temperature
Off Voltage
Actual Voltage
Min. Voltage
Max. Voltage
Min. Current
Max. Current
The controller registers the max. temperature during operation and the time of its
occurrence. The time measurement begins with the first revolution of the motor.
The controller registers the min. temperature during operation and the time of its
occurrence.
The display indicates the actual temperature.
The controller registers the max. current at full throttle, the time at which this value
occurred and the voltage of the flight batteries corresponding with this current. The
measured value corresponds to the current peak which mostly occurs when the motor is
abruptly accelerated.
The controller registers the min. current at full throttle, the time at which this value
occurred and the voltage of the flight batteries corresponding with this current. The
measured value corresponds to the minimum current at full throttle which mostly occurs at
horizontal or descending flight, when the motor is unloaded.
The controller registers the max. voltage of the flight batteries beginning with the first
revolution of the motor as well as the time when this value occurred.
The controller registers the min. voltage of the flight batteries beginning with the first
revolution of the motor as well as the time when this value occurred.
Instantaneous battery voltage.
Value at which the motor has been switched off or its power throttled down as well as the
time, at which this value occurred.
Setting with the help of the JETI-Box
This setting is carried out by means of four push-buttons: left , right , up , down .
Plug in the JR connector of the controller into the plug designated
-
, which is positioned on the right side of
the
JETI-BOX.
Before connecting the flight battery remove for the sake of safety the propeller.
Do not connect anything to the connector designated with -+ .
Connect the flight batteries and switch on the switch (void for Spin11). On the display appears the name of the
connected controller. By means of the push-buttons L and P more detailed informations are acquired of your controller.
By means of the push-button D we get to the option line of basic régimes where we either can choose reading out of
measured values or setting of controller parameters (Measure or Setting), with push-buttons L and P we choose
MEASURE – MAN. SETTING – AUTO SET.
MEASURE
– continue with push-button D
D
D
D
D
D
D
D
D
L
P
N
D
4
Remark concerning current measurements:
1.)
In order to measure correctly, the controller must run at full throttle at least 4 s in the course of the whole flight.
In case of constant rpm setting (Heli const. RPM) this condition may not be fulfilled and the measurement will not
correspond to real values.
2.)
The real average current may travel between the measured value of maximum and minimum current. According
to flying style it may approach one or the other value.