Power ON Time

Motor Pole No.

Motor Run Time

Temperature Protection

Measure or setting

MAN Setting

Errors

Max. Prop RPM

Max. Motor RPM

Gear

The controller registers the overall motor run time. The time is measured from 

the first motor revolution.

The  controller  measures  the  overall  time  from  the  first  switch-on  of  the 

switch (activation of the controller) until switch-off of the controller.

Set  the  number  of  motor  poles  by  means  of  the  push-buttons  L-P

 

.  This 

parameter is important for correct readings of the max. rpm.

Set the gear ratio of the gearbox. Apply 1:1,0 for direct drive

In the course of operation the controller registers the max. motor rpm and the 

time at which these rpm have been achieved.

The controller registers the max. rpm of the propeller in the course of operation 

and the time at which these rpm have been achieved.

If  parameters  have  been  exceeded  –  voltage  (U),  temperatures  (T),  com-

mutation (C) and current (I), protections will be activated and the motor will 

be  cut-off.  The  reading 

y

 means  that  parameters  became  exceeded  (an 

error  occurred),  the  reading 

indicates  that  parameters  have  not  been 

exceeded.

With  the  help  of  this  error  notification  the  cause  of  motor  cut-off  can  be 

determined.

Remark. 

Protection in case of incorrect commutation (C) 

– if operation 

becomes  unsafe  due  to  many  commutation  errors  as  a  result  of  incorrect 

motor design. In some cases this problem can be solved by increasing the 

motor timing.

Return to the main 

menu

With the aid of push-buttons L-P the level of the controller temperature 

protection can be set.

D

D

D

D

D

D

D

D

D

5

Certain parameters of the controller can be set or checked manually.

Summary of Contents for SPIN 11

Page 1: ...Controllers SPIN 1...

Page 2: ...ation see to it that the connectors stay clean and the plug in force remains high If this force decreases replace the connectors immediately We recommend replacement of connectors after 1 2 flight sea...

Page 3: ...is reached groups of three tones mode 3 Glider inrunner this mode is appointed to gliders driven by motors of classic conception inrunner brake activated timung 0 gradual switching off when 68 of the...

Page 4: ...red Instantaneous battery voltage Value at which the motor has been switched off or its power throttled down as well as the time at which this value occurred Setting with the help of the JETI Box This...

Page 5: ...registers the max rpm of the propeller in the course of operation and the time at which these rpm have been achieved If parameters have been exceeded voltage U temperatures T com mutation C and curren...

Page 6: ...ons L P Speed of braking time between the begin of braking and attainment of the preset final braking effekt The time is set by push buttons L P Setting for model helicopters with speed regulation Set...

Page 7: ...5 and more seconds Enter by means of the push buttons L P the type of flight battery For NiCd NiMh cells the min voltage per cell is entered by push buttons L P For LiIon LiPol batteries we can either...

Page 8: ...lue is exceeded no extension of the regulation range occurs Regulation curve Logarithmical a logarithmic course of rpm with the throttle stick displacement linear power course with the throttle stick...

Page 9: ...erted between every cable section longer than 25 30 cm Remark 2 Multi motor models We recommend to use the same controller type for each motor In case of SPIN controllers switch on only one BEC The sw...

Page 10: ...inrunner Off Voltage Set Cut Off LiIo Po cut off V Per Cell Throttle Curve Auto Inc End Point End Point Initial Point Auto Temperature Protection Brake Manual Setting Number of cells Battery Type LiIo...

Reviews: