EN
Init Point Type - AUTO
:
In this mode the Mezon will automatically set the initial point
based upon what it detects as the low throttle position when the ESC/receiver are
switched on. This happens within the first half second once the ESC is powered.
(Recommended)
Init Point Type - FIXED:
In this mode you can set the Initial(arming) and End Points as
fixed values in ms. The Initial Point and End Point positions are displayed only when the
FIXED Init Point Type is selected.
Initial Point –
This is the user defined value of the initial point. If the selected value is
lower than the actual throttle value, the controller/motor will sound an error tone.
End Point –
This is the defined full throttle position value.
Note
-
For safety reasons, the “Init Point” and “End Point” can be only changed if the
controller does not receive any signal from the receiver. If a control signal is detected no
changes can be made.
AutoInc EndPoint –
The automatic extension of the range when the End Point position
pulse width exceeds the defined value.
Fixed End Point –
User defined, fixed END POINT position value for 100% throttle.
Overstepping this value has no effect as the throttle output is already at 100% (regardless
of stick position).
Default setting –
By pressing and holding either the left/right key in this screen resets
the controller to its default settings.