background image

 

 

Extension table assembly

 

Attach the extension bracket (E, Fig. 
6) to the side of the motor (D) with 2 
socket head cap screws (F). 

 

Fig 6 

Slide the shaft of the extension table 
(C) into the extension bracket and 
tighten with lock knob (G). 

 

5.3 Mains connection 

Mains connection and any extension 
cords used must comply with 
applicable regulations. 
The mains voltage must comply with 
the information on the machine 
licence plate.  

The mains connection must have a 16 
A surge-proof fuse. 

Only use power cords marked 
H07RN-F 

Connections and repairs to the 
electrical equipment may only be 
carried out by qualified electricians.  

In case of machine overload the motor 
overload cut-off will react. 
After appr.5 min of cooling the 
overload cut off can be reset. 

Attention: The machine will start 
when you reset the overload push 
button! 
(Only 230V version) 

5.4 Dust connection 

Before initial operation, the machine 
must be connected to a dust extractor. 
The suction should switch on 
automatically when the belt sander is 
switched on. 

The flow rate on the suction port must 
be 20m/sec. 
Flexible hoses must be of non-
flammable quality, and must be 
connected to the machine ground 
system. 
 

5.5 Starting operation 

You can start the machine with the 
green on button. The red button on the 
main switch stops the machine. 

After connecting to the power source, 
turn on the power to the machine just 
enough to start the belt rotating and 
then turn off.  Do this several times 
and observe belt tracking. 
If adjustment is necessary refer to 
“Belt tracking adjustment” (chapter 
7.2) 
 

6.  Machine operation 

6.1 Horizontal sanding 

With the sanding platen locked in the 
horizontal position, the removable 
fence (A, Fig. 7) may be used.  
The fence can be secured in place by 
screwing two lock knobs (B) into the 
guide blocks found in the mitre slot. 

Remove the extension table if 
applicable. 

The backstop (C) must be mounted 
and the drum guard must be closed. 

 

Fig 7 

6.2 Vertical sanding

 

With the sanding platen (E, Fig 8) 
locked in the vertical position, the 
backstop (C) must be installed. 

Remove the extension table if 
applicable. 

The drum guard must be closed. 

 

Fig 8 

Any sanding angle can be chosen. 
The adjustable 90°stop is located on 
the back of the machine. 

The mitre gauge (D) may be used. 

The machine table is adjustable in 
height (see chapter 7.5). 

Note: 

With the machine table slightly tilted 
and the workpiece moving 
longitudinally you can achieve an 
aditional oscillation and an improved 
sanding surface. 

 

6.3 Contour sanding 

Open the drum guard (A, Fig 9) and 
tighten the 2 lock knobs (D). 

 

Fig 9 

Mount the extension table (B) and 
clamp it on the desired working height 
with lock knob (C). 

The drum guard must always be 
closed if the extension table is not in 
use. 

 

 

 

 

 

 

Summary of Contents for OES-80CS

Page 1: ...clarations and agreements concerning warranties The warranty period is valid for eight hours of daily use If this is exceeded the warranty period shall be reduced in proportion to the excess use but t...

Page 2: ...the work piece must be observed Do not remove chips and work piece parts until the machine is at a standstill Do not stand on the machine Connection and repair work on the electrical installation may...

Page 3: ...care and adequate resources when lifting the unit up onto the stand B Through the door in the cabinet E attach main unit to stand with two hex cap bolts and two flat washers D Sanding belt installati...

Page 4: ...tton on the main switch stops the machine After connecting to the power source turn on the power to the machine just enough to start the belt rotating and then turn off Do this several times and obser...

Page 5: ...then turn off Do this several times and observe belt tracking Readjust if necessary 7 3 Tilting angle adjustment Disconnect the machine from the power source Pull handle A Fig 12 forward to release t...

Page 6: ...t by a qualified electrician 9 Trouble shooting Motor doesn t start No electricity check mains and fuse Defective switch motor or cord consult an electrician Overload has reacted Wait and reset overlo...

Page 7: ...eltend gemacht werden Weitergehende Anspr che sind ausgeschlossen Die vorliegende Garantie umfasst s mtliche Garantieverpflichtungen seitens des Verk ufers und ersetzt alle fr heren Erkl rungen und Ve...

Page 8: ...ntration entsteht verwenden Sie stets eine geeignete Absauganlage Holzstaub ist explosiv und kann gesundheitssch digend sein Insbesondere tropische H lzer und harte H lzer wie Buche und Eiche sind als...

Page 9: ...mplett montiert 5 2 Montage Wenn Sie beim Auspacken einen Transportschaden feststellen benachrichtigen Sie umgehend Ihren H ndler nehmen Sie das Ger t nicht in Betrieb Entsorgen Sie die Verpackung bit...

Page 10: ...e nur Anschlussleitungen mit Kennzeichnung H07RN F Anschl sse und Reparaturen der elektrischen Ausr stung d rfen nur von einen Elektrofachkraft durchgef hrt werden Bei berlastung des Motors schaltet d...

Page 11: ...10 Die Sterngriffschrauben B Fig 10 l sen und die Schleifbandabdeckung A entfernen Die Bandspannung mittels Hebel C l sen Das Schleifband vorsichtig entnehmen Neues Schleifband auflegen dabei auf ang...

Page 12: ...regelm igen Abst nden die korrekte Einstellung der Bandf hrung Entspannen Sie das Schleifband bei l ngeren Arbeitspausen Reinigen Sie die Maschine in regelm igen Zeitabst nden Pr fen Sie t glich die a...

Page 13: ...arantie dans les 12 mois suivant la date de la vente date de la facture Toute autre pr tention est exclue La pr sente garantie comprend toutes les obligations de garantie incombant au vendeur et rempl...

Page 14: ...durs tels que le h tre et le ch ne sont class es comme tant canc rig nes Retirer les clous et autres corps trangers de la pi ce avant de d buter l usinage Ne jamais mettre la machine en service sans l...

Page 15: ...dans le sachet avec les tampons Fig 1 Fixer les panneaux lat raux C Fig 1 au panneau frontal D Fig 1 avec 4 vis borgnes 8 rondelles plates 4 rondelles d arr t et 4 crous hex E Fig 1 Fixer la plaque de...

Page 16: ...use Vitesse minimale de l aspiration 20 m s N utiliser que des tuyaux d aspiration de la qualit difficilement inflammable et int grer les tuyaux dans la mise la terre de la machine 5 5 Mise en exploit...

Page 17: ...e D connecter la machine du r seau Tirer la bande la main dans le sens indiqu sur le carter de la bande La bande doit circuler au centre du rouleau Fig 11 Desserrer le contre crou A Fig 11 Maintenant...

Page 18: ...diatement toutes pi ces endommag es ou us es R installer les dispositifs de protection imm diatement Tous travaux de branchement et de r paration sur l installation lectrique doivent tre ex cut s uniq...

Reviews: