04/2014
Operating Manual E4-2800/4200/5200 / M4-3000/4000/5500
Page 41
8.3 MIG/MAG - normal welding and brazing
Two-knob operation
Wire feed speed and voltage must be adjusted separately.
1. Commissioning of the device (see
2. Starting the device with the power switch (Pos. 5, Fig. 5-2)
3.
Select
„Norm“
by pressing the key
4. Selection of welding parameters
Section
Section
•
Selection of the desired wire feed speed via the rotary pushbutton (E). The display
shows the selected value in m/min.
•
Adjust the voltage level with rotary pushbutton (V)
•
Adjustment of choke setting:
Adjustment by pressing the rotary pushbutton (V).Display flashes, % is displayed
Adjustment of choke values with rotary pushbutton (V)
0%
=
hard arc (low choke effect)
100% =
soft arc (high choke effect)
5. Selection of advanced parameters (see
6. Welding with the pre-set values
V
E
9
8