04/2014
Operating Manual E4-2800/4200/5200 / M4-3000/4000/5500
Page 31
6.3.6 Adjustment of voltage / arc length correction
Section
Adjustment of voltage / arc length correction
Fig. 6-14
Display for:
•
Voltage value [V] Arc length correction [%]
•
Choke adjustment [%] Pulse dynamics [%]
•
Time
•
„Hold-value“ voltage
•
Rotary pushbutton for pre-set values
Turning functions:
•
Selection voltage value / arc length correction
•
Adjustment choke value / pulse dynamics
•
By turning the rotary pushbutton (V), a voltage value / arc length correction can be selected.
By alternatively pressing the pushbutton, the following parameters can be adjusted:
•
Voltage value [V]
: Norm
+/- value
•
Arc length correction [%]
: Synergic / Pulse
+/- value
•
Choke adjustment [%]
: Norm / Synergic
+/- value
•
Pulse dynamics [%]
: Pulse
+/- value
•
Time [sec]
Operating mode
: 2-cycle - spot
time value
At weld end, the voltage value achieved during welding is displayed
(„Hold-value “ voltage). In order to display the pre-set values, press the
rotary pushbutton .
V
9
V