MINIMUM GAUGE FOR CORD SETS

VOLTS

AMPERE RATING

MORE THAN NOT MORE THAN

AMERICAN WIRE GAUGE

120 V

0 A

0-25

26-50

51-100

101-150

(0 - 7.6 m)

(7.6 - 15.2m)

(15.2 - 30.4m)

(30.4 - 45.7m)

0-50

51-100

101-200

201-300

(0 - 15.2m)

(15.2 - 30.4m) (30.4 - 60.9m)

(60.9 - 91.4m)

240 V

TOTAL LENGTH OF CORD IN FEET

6 A

10 A
12 A

6 A

10 A
12 A
16 A

18

18
16
14

14

12
12

16

16
16
12

16

14
14

NOT RECOMMENDED

POWER CORD SAFETY

This unit has a polarized plug (one blade is wider than the other) as a safety feature. This plug will fit into a polarized outlet only 

one way. If the plug does not fit fully into the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not 

attempt to defeat this safety feature. WARNING: An imporper connection can result in electrical shock. 

DIGITAL DISPLAY

6V BATTERY / 12V BATTERY  

NOTE: If wrong voltage is selected for 6V battery 

(12V charge) “LO” will display.

* Refer to Faults Code Chart on last page.

Displays “LO” when battery capacity is less than 60%.

Displays “60%-90%” when battery voltage goes up gradually.

Displays “FUL” when unit goes into float charge mode.

Displays Error codes when abnormal conditions occur*.

1.

2.

3.

4.

FEATURES

AUTOMATIC SHUT OFF

This unit is designed to automatically shut off once battery charging is complete to prevent overcharging. When charging is 

complete, the digital display will show ”FUL” and the charger has switched to maintenance mode.
MAINTENANCE MODE

Once charging is complete, this unit will automatically go into float charge mode (also known as maintenance mode). In this mode, 

the unit keeps the battery fully charged by delivering a small amount of current, when necessary, to keep the battery at peak charge.
REVERSE POLARITY PROTECTION

If the cables are incorrectly connected to the battery, the red LED indicator will light up and digital display will indicate “F06”. 

Note: this unit will not begin charging if the reverse polarity indicator is lit. 
OVERHEAT PROTECTION

This unit is designed to shut itself off if overheating is detected. Once the unit cools down, it will resume charging automatically.
CONNECTION METHODS

This unit comes with a standard cables with clips.
3A CHARGE RATE

This unit is recommended for charging small batteries such as those used in motorcycles, ATVs, snowmobiles, personal watercraft, 

lawn tractors and golf cars. It is also suitable to maintain larger batteries such as those used in automobile, marine and farm tractors.
LED INDICATOR

A green LED indicates that a 6V battery is being charged.

A green LED indicates that a12V battery is being charged.

A red LED indicates that a fault occurs.

BATTERY MAINTAINER FUNCTIONS

JEGS 3A Battery Maintainer No. 81954 has a charge rate of up to 3 amps. It is designed for charging small batteries and 

maintaining large batteries. It is designed for 6 and12 Volt lead-acid batteries only - conventional automotive, maintenance- 

free, marine deep cycle and gel - used in cars, farm equipment, boats, RVs and SUVs, lawn mower/garden tractors, motorcycles, 

personal watercraft, snowmobiles, ATVs and various application. The JEGS 3A Battery Maintaine features a 3-stage, 

high-efficiency charging technology, built-in control IC that ensures fast, safe and complete charging of serviceable batteries.
Stage One:  Constant Current: When the battery is severely discharged, the battery maintainer applies constant current.  

 

This stage speedily charges the battery while protecting the battery. 

Stage Two:  Constant Voltage: This is a speed charge cycle for batteries that are nearly fully charged. It will top-off the  

 

battery utilizing a 200mA trickle charge.

Stage Three:  Floating Constant Voltage: This stage maintains a fully charged battery in the best condition by constantly  

 

applying a small pulse  of charge. The battery voltage will be maintain at approximate 13.5 Volt DC.

OUTDOOR USE EXTENSION CORDS 

When the Battery Maintainer is operated outdoors, use only extension cords intended for use outdoors and so marked.
EXTENSION CORDS 

Make sure the prongs of extension cord plug are the same number, size and shape as those on this unit and that the 

extension cord is in good condition. When using an extension cord, be sure to use one that is rated to carry the current your 

product will draw. An undersized extension cord will cause a drop in line voltage resulting in loss of power and overheating. 

The following table shows the correct size to use depending on cord length and nameplate ampere rating. If in doubt, use 

the next higher rated gage. The smaller the gage number, the higher the amperage load rating of the extension cord.

PREPARING TO CHARGE A BATTERY (6 Volt or 12 Volt)

1. Determine the voltage of the battery to be charged by referring to the vehicle owner’s manual.

2. If it is necessary to remove the battery from a vehicle for charging or for cleaning the terminals/posts, always remove the  

  battery grounded terminal/post connection first. Make sure all accessories in the vehicle are off, so as not to cause an arc.

3. Clean battery terminals. Do not allow corrosion to come in contact with eyes.

Summary of Contents for 81954

Page 1: ...ubmerge this unit in water or expose unit to snow or heavy moisture To reduce risk of electric shock disconnect the unit from any power source before attempting maintenance or cleaning Powering OFF controls without disconnecting will not reduce this risk Do not charge a 6 or 12 Volt lead acid battery while the vehicle engine is operating Do not operate the maintainer on boats boat ramps or docks s...

Page 2: ...D INDICATOR A green LED indicates that a 6V battery is being charged A green LED indicates that a12V battery is being charged A red LED indicates that a fault occurs BATTERY MAINTAINER FUNCTIONS JEGS 3A Battery Maintainer No 81954 has a charge rate of up to 3 amps It is designed for charging small batteries and maintaining large batteries It is designed for 6 and12 Volt lead acid batteries only co...

Page 3: ...arging capacity refer to the Approximate Charging Times section for battery charging durations 2 As the battery nears full charge capacity the unit s output charge rate will automatically drop and FUL will show 3 The battery is fully charged and enters the Stage Three Automatic Float Charging AUTOMATIC FLOAT CHARGING NOTE Automatic Float Charging is ideal for maintaining a fully charged battery 1 ...

Page 4: ...e Charging in cold temperatures will increase the amount of time required to charge a battery Find your battery s CCA rating in the table below and note the charging time The time reflects a battery with at least 50 charge You may need to add time depending on the severity of discharge CARE AND MAINTENANCE Withproper careandminimalmaintenance theJEGS 3A Battery Maintainer No 81954will provide year...

Page 5: ...a unidad en agua ni exponga la unidad a la nieve o humedad extrema Para reducir el riesgo de descarga eléctrica desconecte la unidad de cualquier fuente de potencia antes de intentar el mantenimiento o limpieza Los controles del interruptor de apagado sin desconectar la unidad no reducirán este riesgo No cargue una batería de plomo ácido de 6 ó 12 voltios mientras el motor del vehículo esté funcio...

Page 6: ...tería de 6 voltios se está cargando Una luz LED verde indica que una batería de 12 voltios se está cargando Una luz LED roja indica que una occure una falla FUNCIONES DEL CONSERVADOR DE BATERÍA El conservador de 3A de JEGS No 81954 tiene un nivel de carga de hasta 3 amperes Está diseñado para cargar sólo baterías pequeñas y conservar baterías grandes Está diseñado para baterías de ácido de plomo d...

Page 7: ...ivelada 2 Coloque el conservador de baterías tan lejos de la batería como lo permitan los cables IMPORTANTE a NUNCA coloque el conservador de baterías directamente arriba de la batería que va a cargar los gases de la batería corroerán y dañarán el conservador de baterías b NUNCApermitaqueelácidodelabateríagoteesobreelconservador alleerlagravedadespecíficaoalllenarlascélulasdelabatería c NUNCA haga...

Page 8: ...una carga Cargar en temperaturas frías incrementará el tiempo requerido para cargar una batería Encuentre la tasa de amperes en arranque en frío AAF de su batería en la tabla siguiente y apunte el tiempo de carga Los tiempos reflejan una batería con por lo menos 50 de carga Puede ser necesario agregar tiempo dependiendo de la severidad de la descarga CUIDADO Y MANTENIMIENTO Con un cuidado apropiad...

Reviews: