Chapter 6
Configuring Tests
Specifying test configuration settings
42
SmartClass ADSL/Copper Tester User’s Guide
6
Select
IP ADDRESS
, and then enter the IP address.
7
Select
PORT NUMBER
, and then specify the port number.
The port settings are configured.
Specifying Copper settings
If you purchased the Copper/ADSL combo version of the tester (the “Gold”
package), you will need to specify copper settings. The following procedure
describes how to specify the Copper settings.
To specify Copper settings
1
Select
COPPER TEST
from the Main Menu.
2
Select
SETUP
.
The Setup menu appears.
3
Press the
1
key and then specify the DEFAULT PAIR.
4
Press the
2
key and then specify the CABLE TYPE.
5
If you selected CUSTOM as the cable type, additional settings must be
specified.
a
Specify the mutual values (nF/mile or nF/Km).
b
Specify the ground values (nF/mile or nF/Km).
6
Press the
3
key and then specify the CABLE GAUGE.
7
Press the
4
key and then specify the TEMPERATURE.
8
Press the
5
key and then specify the SYSTEM UNITS: Metric or US.
9
Press the
6
key and then specify the default TERMINATION.
10
Press the
7
key to view the LIMITS screen.
a
Press the
1
key and then specify the PASS and FAIL values for
AC VOLTS.
b
Press the
2
key and then specify the PASS and FAIL values for
DC VOLTS.
c
Press the
3
key and then specify the PASS and FAIL values for RESIS-
TANCE.
d
Press the
4
key and then specify the threshold value (length) for
OPEN.
e
Press the
5
key and then specify the percent for a CAP (capacitive)
BALANCE.
f
Press the
6
key and then specify the threshold value for longitudinal
BALANCE.
The copper settings are specified.
Summary of Contents for SC-ADSL-A
Page 1: ...SmartClass ADSL Tester Copper Tester and ADSL Copper Tester User s Guide...
Page 2: ......
Page 3: ...SmartClass ADSL Tester Copper Tester and ADSL Copper Tester User s Guide...
Page 6: ...iv SmartClass ADSL Copper Tester User s Guide...
Page 14: ...About this Guide Conventions xii SmartClass ADSL Copper Tester User s Guide...
Page 26: ...Chapter 2 Quick Tour Using the keypad 12 SmartClass ADSL Copper Tester User s Guide...
Page 48: ...Chapter 5 Copper Testing Calibrating the unit 34 SmartClass ADSL Copper Tester User s Guide...
Page 84: ...Chapter 9 Troubleshooting Resolving problems 70 SmartClass ADSL Copper Tester User s Guide...
Page 89: ......