© 2016, JCM American Corporation
1 - 7
General Information
Section 1
Environmental Specifications
Electrical Specifications
Structural Specifications
Table 1-5
GEN5 Environmental Specifications
Operating Temperature:
+5ºC to +50ºC (41ºF to 122ºF)
*
*. Depends on hydrothermal conditions.
Storage Temperature:
-20ºC to +75ºC (-4ºF to 167ºF)
Relative Operating Humidity:
5% to 85% RH (non-condensed)
Relative Storage Humidity:
5% to 85% RH (non-condensed)
Visible Light Sensitivity:
Interior lighting must be incandescent with a Radiant Angle of 15 Degrees or more having an
Illumination index of 3000 Lux or less
Installation:
Indoors Only
Table 1-6
GEN5 Electrical Specifications
*
*. Power Supply should be UL Listed or IEC Certified and marked “Class 2” or “LPS”.
Supply Voltage:
24V DC (Greater than 3.7A)
Current Consumption:
24V DC
•
Standby = 100 mA
•
Operation = 2.7 A
•
Peak = 4.5 A
Table 1-7
GEN5 Structural Specifications
Weight:
Approximately 1.22kg (2.7lbs.)
Mounting:
Horizontal
Outside Dimensions: