2.2.4 CHIMNEY INSTALLATION:
1. For optimum performance, the minimum chimney height from Load-Bearing Support to roof cap is
4.6m (15’) to 5.2 m (17’). Additional height will increase draft and decrease the tendency to smoke. If
only the minimum chimney height is installed, operating conditions must be optimal; interior chim-
ney, minimum height of 45cm (18”) of chimney before any offset, and total respect of the chimney
manufacturer installation instructions. There is only one offset permitted in the whole smoke
pipe/chimney system, only two 45
o
elbows are permitted with a straight section connecting
them
.
The chimney must extend at least 915 mm (3’) above its point of contact with the roof and at
least 0.6 m (2’) higher than any roof ,wall, or adjacent building within 3 m (10’) of it. The maximum
height of unguided chimney above the roof is 1.5m (5 ft).
8’’chimneys approved to CAN/ULC-S629-M87 Std. (Canadian installations)
Industrial
Chimney
Company.
Excel 203mm (8’’)
(Ext.Dia.254mm(10’’)
Security
Chimneys
International
Secure Temp ASHT +
203mm (8’’) (Ext. Dia.
254mm(10’’)
Secure Temp
TM
S2100+ 203mm
(8’’) (Ext. Dia.
305mm (12’’)
Oliver Mac Leod Projet
Nova-Temp
TM
203mm (8’’) (Ext. Dia.
305mm(12’’)
Selkirk
SuperPro 2100 203mm
(8’’) (Ext. Dia.
305mm(12’’)
SuperVent 2100
203mm (8’’) (Ext.
Dia. 305mm(12’’)
Ultimate One
203mm (8’’) (Ext. Dia.
254mm(10’’)
Selkirk (cont.d)
CF Sentinel
203mm (8’’) (Ext. Dia.
330mm(13’’)
Simpson
DuraVent
DuraPlus HTC
203mm (8’’) (Ext. Dia.
305mm(12’’)
8’’chimneys approved to UL-103HT Standard (USA installations)
Industrial
Chimney
Company.
Excel 203mm (8’’)
(Listing # 5965)
(Ext.Dia.254mm(10’’)
Security
Chimneys
Int’l
Secure Temp ASHT +
203mm (8’’)
(Ext.Dia.254mm(10’’)
Selkirk
SuperPro 2100 203mm
(8’’) (Ext. Dia.
305mm(12’’)
SuperVent 2100
203mm (8’’) (Ext. Dia.
305mm(12’’)
Ultimate One
203mm (8’’) (Ext. Dia.
254mm(10’’)
Selkirk
(cont.d)
UltraTemp 203mm (8’’)
(Ext. Dia. 254mm(10’’)
SuperPro 203mm (8’’)
Ext. Dia. 254mm(10’’)
SuperVent 203mm (8’’)
(Ext. Dia. 254mm(10’’)
Simpson
DuraVent
DuraPlus HTC 203mm
(8’’) (Ext.Dia.305mm
(12’’)
DuraPlus 203mm (8’’)
(Ext. Dia. 305mm(12’’)
DuraTech 203mm (8’’)
(Ext. Dia. 254mm(10’’)
NOTE: NFPA 211 requires that all chimneys used on solid fuel residential applications to be
listed to UL 103HT Standard.
Warning: The installer must follow the chimney manufacturer’s installation instructions to the letter.
Failure to heed these instructions may cause a fire which could result in loss of life or serious