Chimney with 1’’ thick sidewall shown. Chimney with 2’’ thick sidewall shown.
e.g. ASHT 203mm (8’’) w/Std. Load Bearing e.g. S2100 203mm (8’’) w/Special Load
Support 357mm (14 1/16’’) wide Bearing Support 406mm (16’’) wide
Page 10
TYPICAL CONNECTION OF A
BORDELET CENTRAL FIREPLACE
TO A PREFABRICATED 203mm
(8’’) INTERNAL DIAM. CHIMNEY
CONFORMING TO THE
FOLLOWING STANDARDS:
IN CANADA: ULC-S-629
IN THE U.S.A.: UL- 103HT
Caution: A chimney servicing a
fireplace shall not serve any other
appliance. The chimney shall extend
at least 915mm (3 ft) above its point of
contact with the roof and at least 0.6
m (2’) higher than any roof ,wall, or
adjacent building within 3m (10 ft) of
it. The maximum height of unguided
chimney above the roof is 1.5m (5
ft).