1 Switch field “Settings” (the way to all possible settings)
2 Status line Alarm with adjusted limit values for pH and temperature
3 Status line Hysterese (Hysteresis) with adjusted value
4 Actual pH value (current pH value in buffer or in your aquarium)
5 Status line Auto pH with adjusted KH (Carbonate Hardness)
6 Current temperature (in illustration flashing read in the alarm status)
7 Valve status
8 Time to calibration (days/hours)
9 Sensor voltage in mV
10 Actual precision of measurement (re-calculated for each calibration)
11 pH set point (required pH value, controlled by device through CO₂ supply)
12 Warning triangle (will flash a warning, while the actual value flashes in red)
13 Key lock (unlocked in illustration)
pH set point adjustment
If you are using a pH computer for the first time, we strongly recommend the initial use of
the auto pH function to adjust the pH set point:
Touch the switch field “Settings” and select the menu point “Auto pH” by tapping on the
arrow symbols. Confirm with “OK”. Enter the present KH value of your aquarium water by
pressing the fields “plus” or “minus”. Confirm with “OK”. Measure by all means the KH level in
your aquarium by means of a KH test, such as the JBL KH test kit.
The device now calculates the optimal pH value for this KH and saves it as set point. Based on
the calculation is a CO₂ content of 22.5 mg/l, which is considered as optimal.
DE
UK
FR
NL
IT
ES
PT
SE
CZ
PL
RU
RO
TR
Summary of Contents for PROFLORA pH Control Touch
Page 2: ...1 a...
Page 3: ...2...
Page 4: ......
Page 8: ...4 Kalibrierung...
Page 29: ...25 DE UK FR NL IT ES PT SE CZ PL RU RO TR Calibration...
Page 50: ...46 talonnage...
Page 71: ...67 Kalibratie DE UK FR NL IT ES PT SE CZ PL RU RO TR...
Page 92: ...88 Calibratura...
Page 113: ...109 DE UK FR NL IT ES PT SE CZ PL RU RO TR Calibraci n...
Page 134: ...130 Calibra o...
Page 155: ...151 DE UK FR NL IT ES PT SE CZ PL RU RO TR Kalibrering...
Page 195: ...191 DE UK FR NL IT ES PT SE CZ PL RU RO TR Kalibracja...
Page 216: ...212...
Page 217: ...213 7 00 4 00 calibration o k 4 2 3 7 1 7 13 30 CO DE UK FR NL IT ES PT SE CZ PL RU RO TR...
Page 218: ...214 6 5 4 3 2 1 7 8 9 10 11 12 13 1 2 3 4 5 Auto pH KH 6 7 8 9 10 11 CO 12 13 Auto pH...
Page 226: ...222 OK 0 10 2 00 0 05 1 00 CO 0 50 CO 20 C t 30 C 4...
Page 228: ...224 OK locked unlocked OK locked OK OK 7422 4 software version Software Version OK...
Page 230: ...226 4 5 2 sensor defect DELTAV OFFSET DELTAV 35 7 00 OFFSET pH 7 00 4 00 7 00...
Page 232: ...228 24 JBL 2 3 JBL JBL pH Sensor 24 JBL JBL PROFLORA pH...
Page 238: ...234 Calibrare...
Page 259: ...255 DE UK FR NL IT ES PT SE CZ PL RU RO TR Calibration Kalibrasyon...
Page 277: ...273...