Jaypro Retractable Practice Cages - Installation and Operating Instructions
www.jaypro.com / (800) 243-0533 / 976 Hartford Tpke, Waterford, CT 06385 USA
SUBJECT TO CHANGES IN DESIGN AND MANUFACTURING
COPYRIGHT 2017 JAYPRO SPORTS, LLC. ALL RIGHTS RESERVED
BBC-700 REV B, RELEASED 12-29-2017
Sheet 22 of 26
ELECTRICAL NOTES:
- Circuit breaker rating: 20 amp
- Fused circuit rating: 20 amp
- Size of wall masonry box required for single key switch (KS-13): 2" W x 3-3/4" H x 2-1/2" D.
Location of box must be within full view of batting cage.
- Proper motor performance is based on 115 volts at the motor terminals; Gauge wire accordingly.
Voltages of less than 115 volts could damage the motor and will void the warranty.
- All wires, wiring, conduit and device boxes shall be supplied by the electrical contractor.
Do not gang the neutral wires. The electrical contractor shall wire to all national and
local codes and ground properly.
ELECTRIFY THE WINCH:
1.
A licensed electrician should perform the final electrical hook ups.
HOIST THE CAGE FRAME OFF THE GROUND TO APPROXIMATELY 4-1/2' TO 5' ABOVE FINISHED FLOOR.
Figure 27: Winch (CW-1800) Wiring Diagram for Key Switch (KS-13) Operation
DRY CONTACTS
RATED FOR 1 HP MOTOR
(e.g. KEY SWITCH (JAYPRO KS-13),
RELAYS (JAYPRO MEC2 / ETEC), etc.)
TERMINAL
BLOCK
11
Blue (Down)
White
Green
Red (Up)
12
18
Black
CUSTOMER
SUPPLY 115 VAC
Hot
Neu
Gr
1 , 60 Hz
10 AMP FLA
1 HP, 115 VAC
M
UP (Red)
DOWN (Black)
COMMON (White)
GROUND (Green)
G G
1
4
8 8
4
1
LOWER
LIMIT
UPPER
LIMIT
R
ed
B
lu
e
W
hi
te
CW-1800 WIRING DIAGRAM