Page 27 / 41
Ref doc :
330740F/EN
revision 01
29.09.2015
On the sides of the unit, we recommend:
Mounting the charger support
To avoid any ambiguity when the radio remote control is inactive, placed on its charger, we recommend that you do
not mount the charger support in a way which is directly visible by the operators. For example, a protective screen
plate could be used as shown in the photo below.
On the top of the housing, we recommend :
Mounting an indicator light assembly.
The indicator light column will show the state of the equipment and the radio remote control transmitter. The
indicator light column information sheet should be fastened near the indicator light column (See example given on
last page of manual).
7.3.1 Special case
– Equipment area access
For an area access configuration (application program 8 or 9), an access authorization request pushbutton must be
wired on either side of the area access. The two buttons will allow the operator to access and exit the intervention
area. See wiring diagram in section
6.2.2
“Control of machine with area access control.”
7.3.2 Receiver antenna installation position
Supplied with the product is an antenna, a 50 cm antenna extender and a BNC-BNC elbow.
If a metal electrical housing is used, the receiver antenna should be remote-mounted on the top of the housing.
If a plastic housing is used, the receiver antenna can be connected directly on the RADIOSAFE receiver.
In the event of poor radio wave propagation, for example when intervening in an enclosure, we recommend that the
receiver antenna be remote-mounted inside the enclosure.
Contact us for the choice of antenna extension.
Indicator light column
information sheet
Product mounted in housing