Page 10 / 41
Ref doc :
330740F/EN
revision 01
29.09.2015
The RSRA receiver has the following outputs :
100 mA opto-coupled static outputs :
6 function outputs
Safety relays :
2 guided-contact safety relays « 3 N0 ».
Safety outputs and inputs
Terminals Function
A1+
24VDC power supply for safety modules of receiver (RSRA)
A2-
Common ground
48
24V static output: safety module status
58
24V static output: safety module status ( of witch catch transmitter of charger)
S11
S12
Input 1 for 1
st
emergency stop or 1
st
safety barrier
S13
S14
Input 2 for 1
st
emergency stop or 1
st
safety barrier
S21
S22
Input 1 for 2nd emergency stop or 2nd safety barrier
S23
S24
Input 2 for 2nd emergency stop or 2nd safety barrier
S31
S32
Input for test of 1
st
charger
S33
S34
Input for test of 2
nd
charger
S42
Input for wired
“ON” button
Y1
Y2
Input for auxiliary relay return loop
13
14
1
st
safety output (NO contact)
23
24
2
nd
safety output (NO contact)
33
34
3
rd
safety output (NO contact)
Removable connection
block, screw terminals
White. lights, V1 & V2
«Safety module status»
Green ind. lights, K1 and K2
«Safety relay status»
Green indicator light V4
«Radio reception quality»
Antenna
BNC connector
Red indicator light V3
«wrong identity code»