9.2.3 Receiver input fault isolation
The various operating states leading to deactivation of the safety outputs are
indicated by an error code (No.)
simultaneously by the white LED "V2" and static output 58
.
The white LED « V1 » remains on. So long as the cause of the fault has not been eliminated, static output 48 is
activated. It flashes regularly as soon as reactivation of the module by one of the ON button is possible.
Error code
(number of
consecutive
flashes of white
ind. light « V2 » )
State
Cause
1
Radio transmitter
emergency stop
- A charger contact is open and the emergency stop
palmswitch on the remote control is pressed.
- A charger contact is open and radio communication has
not been activated.
2
System stopped by a
wired protection
component
One of inputs S12-S14 or S22-S24 is deactivated.
3
Time delay error
The contacts of a safety element have not been activated
within the required time frame. The contacts of this
component must first be deactivated before a new activation
can be recognised.
- The charger contact has been opened, but radio
communication has not been activated in time.
- In « protected area access » mode, the passage button or
the ON button on the remote control has not been released
after the passage request stop.
4
Error in one of the ON
buttons
- Activation time greater than time delay duration selected.
- Activated on power up of module.
- Activated on appearance of a fault.
5
Passage button error
Protected area access mode, button (S34) activated at
moment of power up.
6
Charger contact error
Only one of the two charger contacts is open.