background image

Jason International, Inc.  •  

 

501.771.4477  

 

 

 

Page 1 of 18

 

 

 

 

Customer Service :  800.255.5766 

Copyright © 2014 Jason International.

“TO BE REMOVED FOR USE BY THE OCCUPANT.”

49-1010-801

Date   05/2018

OWNER’S MANUAL

forma

®

 and Designer MicroSilk

®

-AirMasseur

®

 Baths

INSTALLATION, OPERATION, AND MAINTENANCE

Jason International, Inc.

8328 MacArthur Drive

North Little Rock, AR 72118-2029

www.jasoninternational.com

MADE IN THE USA

OWNER’S RECORD

Dealer: 

Date Purchased: 

Date Installed: 

Installer: 

PLACE SERIAL NUMBER CARD WITH 

PRODUCT CONFIGURATION IN THIS BOX

INSPECTION

Inspect the unit prior to installation. In the event of a 
problem, DO NOT install the unit.

 

All components are factory assembled to the bath and the 
unit is water tested and inspected prior to leaving Jason 
International, Inc.

If the carton shows sign of damage, inspect the product 
before accepting and describe the problem on the 
Bill of Lading.

NOTE: Transportation and insurance from Jason’s 
factory are the buyer’s responsibility.

Damage sustained in transit is the responsibility of 
the carrier.

 If damage is discovered, the carrier must 

be immediately notified in writing with a request for a 
representative to inspect the unit. Failure of the carrier 
to respond should be reported to the seller and carrier. 
Always file a freight claim promptly.

The installer is responsible for ensuring that the unit is 
free from defects or shipping damage. 

In the event of a 

problem, DO NOT install the unit. 

Jason International is not responsible for damage that 
might have been avoided by inspection or testing prior to 
installation.

If the carton shows sign of damage, inspect 
the product before accepting and describe the 
problem on the Bill of Lading.

Damage to the unit during installation will not be covered 
by warranty and is the responsibility of the installer. 

ALL WARRANTY CLAIMS ON ACRYLIC SURFACE 
DAMAGE MUST BE MADE PRIOR TO INSTALLATION. 

Inspect plumbing and bath surface for missing or damaged 
components. Alert your dealer of any discrepancies.

To protect the unit from damage, keep the bath in the 
carton until ready for installation.

EQUIPMENT ACCESS

In accordance with Building Codes, service access to 
all hydrotherapy bath equipment, controls and electrical 
connections must be provided during installation 

(Recommended minimum 28" x 17" [71 x 43 cm]). 

Insufficient access will hinder repair and maintenance. 
Warranty service will not cover costs of providing 
equipment access.

Jason offers an optional removable lateral skirt for all 
rectangular baths. The skirts are available in matching 
acrylic colors and provide convenient access to bath 
equipment, as well as an excellent finished appearance.

The Specification Sheet for this bath contains additional 
technical information.  This sheet can be provided by your 
dealer or accessed online at 

www.jasoninternational.com

.

 

Summary of Contents for forma Designer MicroSilk AirMasseur

Page 1: ...responsible for ensuring that the unit is free from defects or shipping damage In the event of a problem DO NOT install the unit Jason International is not responsible for damage that might have been...

Page 2: ...minimum ventilation opening of 2 x 4 5 x 10 cm for the blower is required and should be designed to draw in indoor ambient air at a minimum of 72 F 22 C 4 Install the drain and overflow assembly to t...

Page 3: ...ration and Maintenance manual of the separately packaged MicroSilk hydrotherapy bath unit Full Support B ase Figure 3 Figure 4 WARNING SYSTEM UNDER PRESSURE NEVER PERFORM MAINTENANCE WHILE SYSTEM IS R...

Page 4: ...ed following E T L Guidelines During installation if remote mounting of the blower is desired or required the following procedures should be followed NOTE Do not remote mount the blower more than 15 f...

Page 5: ...Control Box The MicroSilk generator unit may be shippedseparatefromthebath Followtheinstructionsfor theMicroSilk PumpAssemblyFieldInstallationinthe Installation section of this owner s manual instruc...

Page 6: ...Standard Premier Edition Signature Edition Sani Design C leaning Syst em B lower C ont rol B oxes C ont rol Mount L2 L1 GROUND DEDIC ATED 2 4 0 V 5 0 or 6 0 Hz GFC I PROTEC TED SERVIC E NOTE USE THE A...

Page 7: ...e during installation to minimize cleanup and prevent surface damage WATER TESTING Before finishing the installation it is recommended that the bath be water tested and the plumbing tested for leaks 1...

Page 8: ...f Ugtxleg Hgocng Pgoc Nqcf Eqppgevlqp MgCrcf aKFW 288b Dnqygt OU Swor Ocng Pgoc Nlpg Eqppgevlqp MgCrcf Ecdng aEDN 169b Transducer Cables Transducer Cables PqvguB C Ulping Fgflecvgf 120X 60JD 20C IHEK...

Page 9: ...system see note B The MicroSilk pump s power cord should be plugged into the female cord connection on the ozone unit prewired to the control box C Eight pinmini DINterminalfortheMicroSilk AirMasseur...

Page 10: ...B The MicroSilk pump s power cord should be plugged into the female cord connection on the ozone unit prewired to the control box C Eight pinmini DINterminalfortheMicroSilk AirMasseur Keypad D The bl...

Page 11: ...ute pause before the purge cycle begins Once the purge cycle begins all indicators will light and the keypad operation will be disabled for two 2 minutes SIGNATURE EDITION MICROSILK AIRMASSEUR The Jas...

Page 12: ...es 50mm above the jets The inlet temperature should not exceed 40 C 104 F When bath is in use turn the unit Off before draining the water The bath unit and its plumbing are designed to drain after eac...

Page 13: ...gh speed mode Pressing the icon again begins the wave mode indicated by a slow flashing light Pressing the icon a third time will change the blower to pulse mode This is indicated by a rapid light fla...

Page 14: ...2 seconds to turn the lights Off or On Hold the key for more than two 2 seconds to change modes The Light icon should remain lit as long as the bath is connected to a power supply This function has a...

Page 15: ...ll ensure a quick response on warranty items The serial number can be found on the front page of this manual or on the small card adhered to the back of the bath just above the equipment ALL WARRANTY...

Page 16: ...a Refer to installer dealer b Refer to installer dealer Pump operates but water is not being pumped a Suction or discharge blocked b Suction air leak System usually surges a Remove obstruction b Make...

Page 17: ...cted c Check and reconnect if necessary Blower shuts off by itself or before time elapses a Blower motor overheated and thermal protection device deactivated motor possibly low voltage a Check that bl...

Page 18: ...er use the therapy bath while under the influence of alcohol anticoagulants stimulants antihistamines vasoconstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical histor...