Table 5.1 Alarms of the machine and troubleshooting
ALARM
CODE
SHORT DESCRIPTION
USER
DESCRIPTION
USER
ACTION 1
USER
ACTION 2
USER
CAUSE1
USER
CAUSE2
61
ALARM_PWM_INVERTE
R
STARTUP TEST
ERROR
POWER OFF /
POWER ON
CONTACT THE
SERVICE
CENTER
ANOMALY IN THE
POWER INVERTER
CONTROL
BOARFD
FAULT
62
ALARM_V_POWER_MOT
OR
CONTROL BOARD
FAULT
POWER OFF /
POWER ON
CONTACT THE
SERVICE
CENTER
ANOMALY IN THE
MOTOR DRIVER
FAULT
CONTROL
BOARFD
FAULT
63
ALARM_PWM_MOTOR
CONTROL BOARD
FAULT
POWER OFF /
POWER ON
CONTACT THE
SERVICE
CENTER
ANOMALY IN THE
MOTOR DRIVER
FAULT
CONTROL
BOARFD
FAULT
67
ALLARM TABLE
CALIBRATION
CALIBRATION
ERROR
POWER OFF /
POWER ON
CONTACT THE
SERVICE
CENTER
71
ALARM_CTE
THERMAL 2T/4T
ERROR
WAIT COOLING
THE POWER
STAGE A FEW OF
MINUTES
OUT OF LIMIT OF
THE MACHINE
WORKING
72
ALARM_MOTOR_SPEED
MOTOR SPEED
ERROR
CHECK TORCH
CONSUMABLE
PARTS,
PRESSURE OF
THE ROLLS
TORCH QUALITY
BAD MOTOR
FIXING ROOLS
73
ALARM_MOTOR_ENCOD
ER
MOTOR SPEED
ERROR
POWER OFF /
POWER ON
CONTACT THE
SERVICE
CENTER
FAULT OF THE
CONTROL BOARD
FAULT OF THE
SPEED
SENSOR
76
ALARM_MOTOR_BRAKE
MOTOR BRAKE
ERROR
POWER OFF /
POWER ON
CONTACT THE
SERVICE
CENTER
FAULT CONTROL
BOARD
77
ALARM MOTOR
CURRENT
MOTOR ERROR
WAIT ALARM
RESET
POWER OFF /
POWER ON
CONTACT THE
SERVICE
CENTER
TOO STRONG
FIXING ROOLS
BAD QUALITY
OF THE TORCH
80
ALARM DITER STOP
CONTROL BOARD
FAULT / CLOUD
CONNECTION
BOARD FAULT
FOR EVOLVE 200
PRESS THE
RIGHT UPPER
BUTTON TO
RESET THE
ALARM
CONTACT THE
SERVICE
CENTER
FAULT CONTROL
BOARD
FAULT CLOUD
CONNECTION
BOARD
Summary of Contents for EVOLVE 200
Page 1: ...EVOLVE 200 USER MANUAL EVOLVE 200 USER MANUAL REV 20201219 ...
Page 18: ...EVOLVE 200 USER MANUAL 16 ...
Page 43: ...EVOLVE 200 USER MANUAL 41 4 1 Remote control connection ...
Page 50: ...EVOLVE 200 USER MANUAL 48 ...
Page 51: ...EVOLVE 200 USER MANUAL 49 Appendix 2 MACHINE SCHEMATICS ...
Page 53: ...EVOLVE 200 USER MANUAL 51 ...
Page 54: ...EVOLVE 200 USER MANUAL 52 Ref 3 Ref 4 Ref 5 3 5 10 2 7 ...