25
CONTROL PANEL
-
SETTINGS
Configuration Settings (Engineers mode)
Standby Time Adjustment
Standby time is a function that when there is no operator activity with the Jasic TIG machine, then after
a pre
-
determined time (Factory time: 10 minutes) the machine will go into standby (sleep) mode.
To enter the setting screen, press and hold the "Current
Setting dial knob" for 2 seconds and you will note on the
display a countdown will start from 3 seconds to zero,
once the countdown is complete the panel displays
"F01".
To access standby time press the control dial again to
enter this parameter.
Now, rotate the control dial clockwise/anticlockwise to
change the standby response time.
There is four levels to choose from, 0, 5 10, & 15 (where
0 means disabled). 5, 10 & 15 correspond to the response times in minutes. (default value is 10.)
Upon selecting your chosen response time, press the control dial to save the current settings.
Then press the welding mode button
to complete the operation and exit.
The standby function is only available in TIG mode.
The machine will not go into standby mode if a wired foot control is connected.
If the machine is not used within a set period of time (10 minutes for example),
the machine will then enter a standby state where the unit powers down and
only the middle bar of the first digit on the display panel will flash. The flash
rate is at a frequency of 1 blink per second.
The machine will wake up immediately and the screen will show the previous
data when either the torch trigger, remote device or if one of the control panel
buttons are pressed.
Input overvoltage and undervoltage protection
Upon accessing the engineers configuration screen, press and hold the "Current Setting dial knob" for 2
seconds and you will note on the display a countdown will start from 3s to zero, once the countdown is
complete the panel displays "F01".
To access input voltage protection, rotate the control dial until
“
F02
”
is shown in the display and press the control dial again to access this
parameter.
Now, rotate the control dial clockwise/anticlockwise to change the
overvoltage and undervoltage protection setting to either: 0 = Off
and 1 = ON (enabled).
After making your choice, press the control dial to save your chosen setting and then press the welding
mode
button to complete the operation and exit.
This option is factory set to ON, please speak with Jasic technical before interfering with this setting.
Summary of Contents for EVO 2.0 ET-200PACDC
Page 1: ...1...
Page 73: ...73 UKCA Declaration of Conformity...
Page 74: ...74 EC DECLARATION OF CONFORMITY...
Page 80: ...80...