17
CONTROL PANEL
1.
TIG Parameter selection area: Pushing the adjustment knob (8) will highlight the LED of the
parameter to be adjusted in the selection area (model ET
-
200 does not show pulse options).
2.
Digital meter: Displays pre
-
set and actual current as well as displaying the parameter adjustment
settings along with error codes.
3.
Warning indicators:
a. The yellow warning LED will light up if the machine overheats.
b. The red warning LED will illuminate if the machine experiences an input mains under or over
voltage situation.
4.
TIG AC, TIG DC, TIG Hybrid (Mix) and MMA selector and indicators: Allows the operator to switch
between MMA and TIG welding modes via the green button below, the corresponding LED indicator
will illuminate, see pages 39 onwards for further details.
5.
TIG starting mode selection switch (contact or non contact ignition): When you press this switch,
you either select HF arc start ignition or lift arc ignition in TIG mode and the matching indicator will
illuminate.
6.
TIG torch trigger function modes: 2T, 4T, repeat and spot. Press the
‘
mode
’
key to select the
required welding trigger mode and depending on your selected TIG torch trigger option the
corresponding LED indicator will illuminate, see pages 22 and 50 for further details.
7.
Remote control selection: Pressing this button will set current control from the panel to a remote
device such as a foot pedal or a TIG torch remote potentiometer as well as a remote control device
for MMA.
8.
Smart Gas selection, This function will automatically match the post
-
flow gas time to the user
’
s
parameter setup in TIG mode (With Smart Gas turned ON, you can access the post gas time option).
9.
Water Cooling selection button (water or air): Using this switch will turn on/off the fitted TIG water
cooler and the matching indicator will illuminate