background image

 

A WILKINSON STAR LIMITED PRODUCT                                                                                                                                    12-16 ISSUE 1 

Maintenance and troubleshooting 

The following operation requires sufficient professional knowledge on electric aspects and 
comprehensive safety knowledge. Make sure the input cable of the machine is disconnected from the 
electricity supply and wait for 5 minutes before removing the machine covers. 

In order to guarantee that the arc welding machine works efficiently and in safety, it must be maintained 
regularly. Operators should understand the maintenance methods and means of arc welding machine 
operation. This guide should enable customers to carry on simple examination and safeguarding by 
oneself, try to reduce the fault rate and repair times of the arc welding machine, so as to lengthen service 
life of arc welding machine. 

Troubleshooting 

Before cutting machines are dispatched from the factory, they have already been checked thoroughly. 
The machine should not be tampered with or altered. Maintenance must be carried out carefully. If any 
wire becomes loose or is misplaced, it maybe potential danger to user! 

Only professional maintenance personnel should repair the machine! 

Ensure the power is disconnected before working on the machine. Always wait 5 minutes after power 
switch off before opening the case. 

 

Period 

 

Maintenance item

 

Daily examination

 

Check the condition of the machine, mains cables, welding cables and 
connections. 

Check for any warnings LEDs and machine operation. 

Check the air intake is unobstructed. 

Check the torch leads and components 

Monthly examination

 

Disconnect from the mains supply and wait for at least 5 minutes before 
removing the cover. Check internal connections and tighten if required. 
Clean the inside of the machine with a soft brush and vacuum cleaner. Take 
care not to remove any cables or cause damage to components. Ensure that 
ventilation grills are clear.  Carefully replace the covers and test the unit. 

This work should be carried out by a suitably qualified competent person. 

Yearly examination

 

Carry out an annual service to include safety check in accordance with the 
manufacturers standard (EN 60974-4). 

This work should be carried out by a suitably qualified competent person. 

Summary of Contents for CUT80 (L205)

Page 1: ...Operator Manual www jasic co uk Plasma Cut Series Plasma Cut 60 JP 61 Plasma Cut 80 JP 81...

Page 2: ...Call your distributor in the unlikely event of a problem occurring Please record below the details from your product as these will be required for warranty purposes and to ensure you get the correct i...

Page 3: ...ary supply and welding should be regularly checked for damage and overheating Do not use worn damaged under sized or poorly jointed cables Ensure that you wear the correct protective clothing gloves h...

Page 4: ...from flash glare and sparks from the welding area Ensure that there are adequate warnings that welding or cutting is taking place Wear suitable protective flame resistant clothing The sparks and spat...

Page 5: ...electronic equipment as the magnetic fields may cause damage RF Declaration Equipment that complies with directive 2004 108 EC concerning electromagnetic compatibility EMC and the technical requiremen...

Page 6: ...m 50Hz 60Hz input AC voltage to 30K 50KHz AC high voltage The voltage is dropped and rectified to output the DC power supply for cutting This inverter technology provides a machine which is smaller an...

Page 7: ...ensure that the correct supply is available Details of the machine requirements can be found on the data plate of the machine or in the technical parameters shown in the manual The equipment should b...

Page 8: ...he direction to reduce the pressure 7 When the correct pressure is set push down the adjusting knob 8 Turn off the machine 9 Replace the panel and handle Any water which has been collected by the air...

Page 9: ...h to the position about 1mm above the workpiece and start cutting Controls 1 Digital Ammeter 2 Power indicator 3 Warning indicator 4 Pressure guage 5 Current adjustment knob 6 2T 4T selector 7 Air pur...

Page 10: ...when the working temperature of the IGBT is overly high When lit the machine stops working 3 2T indicator It illuminates when the machine is under 2T status 4 4T indicator It illuminates when the mac...

Page 11: ...ly If any wire becomes loose or is misplaced it maybe potential danger to user Only professional maintenance personnel should repair the machine Ensure the power is disconnected before working on the...

Page 12: ...F F PROTECTION CLASS IP 21S IP 21S EFFICIENCY 85 85 MACHINE DISPOSAL Please do not dispose of electrical waste with normal waste products In accordance with the European directive 2002 96 EC regardin...

Page 13: ...A WILKINSON STAR LIMITED PRODUCT 12 16 ISSUE 1 EXPOLDED PARTS LIST JP 61 EXPOLDED PARTS LIST JP 81...

Page 14: ...e 10048389 20 Column 10049874 21 Connector 10049923 22 Handle bar 10058227 23 Quick connector 10004638 24 Power switch 10021935 25 Plastic bolt M3x6 10048737 26 Front support 10058240 27 Front sticker...

Page 15: ...fully cut because the cutting torch is moved too fast or the cutting current is too low Keep the nozzle slightly touching the workpiece or keep a short distance between the nozzle and workpiece If the...

Page 16: ...A WILKINSON STAR LIMITED PRODUCT 12 16 ISSUE 1 JP 61 81 CUT 61 Order code JP 61 CUT 81 Order code JP 81 Wilkinson Star Limited...

Reviews: