A WILKINSON STAR LIMITED PRODUCT                                                                                                                                    12-16 ISSUE 1 

Always ensure machine covers and protective devices are in operation. 

Precautions against fire and explosion 

Avoid causing fires due to sparks and hot waste or molten metal 

Ensure that appropriate fire safety devices are available near the cutting / welding area. 

Remove all flammable and combustible materials from the cutting / welding zone and surrounding areas 

Do not cut/weld fuel and lubricant containers, even if empty. 

These must be carefully cleaned before they can be cut/ welded. 

Always allow the cut/welded material to cool before touching it or placing it in contact with combustible 
or flammable material. 

Do not work in atmospheres with high concentrations of combustible fumes, flammable gases and dust. 

Always check the work area half an hour after cutting to make sure that no fires have begun. 

Risks due to magnetic fields 

The  magnetic  fields  created  by  high  currents  may  affect  the  operation  of  pacemakers  or  electronically 
controlled medical equipment. 

Wearers  of  vital  electronic  equipment  should  consult  their  physician  before  beginning  any  arc  welding, 
cutting, gouging or spot welding operations. 

Do not  go near  welding equipment  with  any sensitive  electronic equipment  as  the  magnetic  fields  may 
cause damage. 

RF Declaration 

Equipment  that  complies  with  directive  2004/108/EC  concerning  electromagnetic  compatibility  (EMC) 
and the technical requirements of EN60974-10 is designed for use in industrial buildings and not those for 
domestic use where electricity is provided via the low voltage public distribution system. Difficulties may 
arise in assuring class A electromagnetic compatibility for systems installed in domestic locations due to 
conducted and radiated emissions. 

In the case of electromagnetic problems, it is the responsibility of the user to resolve the situation. It may 
be necessary to shield the equipment and fit suitable filters on the mains supply. 

LF Declaration 

Consult the data plate on the equipment for the power supply requirements. 

Due  to  the  elevated  absorbance  of  the  primary  current  from  the  power  supply  network,  high  power 
systems  affect  the  quality  of  power  provided  by  the  network.  Consequently,  connection  restrictions  or 
maximum  impedance  requirements  permitted  by  the  network  at  the  public  network  connection  point 
must be applied to these systems. 

In  this  case  the  installer  or  the  user  is  responsible  for  ensuring  the  equipment  can  be  connected, 
consulting the electricity provider if necessary. 

Materials and their disposal 

The  equipment  is  manufactured  with  materials,  which  do  not  contain  any  toxic  or  poisonous  materials 

Summary of Contents for CUT80 (L205)

Page 1: ...Operator Manual www jasic co uk Plasma Cut Series Plasma Cut 60 JP 61 Plasma Cut 80 JP 81...

Page 2: ...Call your distributor in the unlikely event of a problem occurring Please record below the details from your product as these will be required for warranty purposes and to ensure you get the correct i...

Page 3: ...ary supply and welding should be regularly checked for damage and overheating Do not use worn damaged under sized or poorly jointed cables Ensure that you wear the correct protective clothing gloves h...

Page 4: ...from flash glare and sparks from the welding area Ensure that there are adequate warnings that welding or cutting is taking place Wear suitable protective flame resistant clothing The sparks and spat...

Page 5: ...electronic equipment as the magnetic fields may cause damage RF Declaration Equipment that complies with directive 2004 108 EC concerning electromagnetic compatibility EMC and the technical requiremen...

Page 6: ...m 50Hz 60Hz input AC voltage to 30K 50KHz AC high voltage The voltage is dropped and rectified to output the DC power supply for cutting This inverter technology provides a machine which is smaller an...

Page 7: ...ensure that the correct supply is available Details of the machine requirements can be found on the data plate of the machine or in the technical parameters shown in the manual The equipment should b...

Page 8: ...he direction to reduce the pressure 7 When the correct pressure is set push down the adjusting knob 8 Turn off the machine 9 Replace the panel and handle Any water which has been collected by the air...

Page 9: ...h to the position about 1mm above the workpiece and start cutting Controls 1 Digital Ammeter 2 Power indicator 3 Warning indicator 4 Pressure guage 5 Current adjustment knob 6 2T 4T selector 7 Air pur...

Page 10: ...when the working temperature of the IGBT is overly high When lit the machine stops working 3 2T indicator It illuminates when the machine is under 2T status 4 4T indicator It illuminates when the mac...

Page 11: ...ly If any wire becomes loose or is misplaced it maybe potential danger to user Only professional maintenance personnel should repair the machine Ensure the power is disconnected before working on the...

Page 12: ...F F PROTECTION CLASS IP 21S IP 21S EFFICIENCY 85 85 MACHINE DISPOSAL Please do not dispose of electrical waste with normal waste products In accordance with the European directive 2002 96 EC regardin...

Page 13: ...A WILKINSON STAR LIMITED PRODUCT 12 16 ISSUE 1 EXPOLDED PARTS LIST JP 61 EXPOLDED PARTS LIST JP 81...

Page 14: ...e 10048389 20 Column 10049874 21 Connector 10049923 22 Handle bar 10058227 23 Quick connector 10004638 24 Power switch 10021935 25 Plastic bolt M3x6 10048737 26 Front support 10058240 27 Front sticker...

Page 15: ...fully cut because the cutting torch is moved too fast or the cutting current is too low Keep the nozzle slightly touching the workpiece or keep a short distance between the nozzle and workpiece If the...

Page 16: ...A WILKINSON STAR LIMITED PRODUCT 12 16 ISSUE 1 JP 61 81 CUT 61 Order code JP 61 CUT 81 Order code JP 81 Wilkinson Star Limited...