Section 19 Adjusting and Setting up Equipment (for Services)
19-22
19.3.3.1 Displaying the [Serial Port] dialog
When you select [System Configuration] in the first classification pane and [Serial Port] in the second
classification pane, the [Serial Port] dialog is displayed in the edit/result pane.
19.3.3.2 [Diagnosis] lamp light colors
The [Diagnosis] lamp indicates the Diagnosis result on whether or not the sentence of the sensor
specified for each serial port has been received successfully and the status of ISW/MTR/Serial OPU.
Lit in red:
Data not received.
Lit in green:
Data is receiving.
Lit in orange:
In Diagnosis (before decision).
No color:
Serial port is disabled.
19.3.3.3 Setting a serial port
In the [Serial Port] dialog, allocate the sensors to be connected for the serial port on CCU (Central
Control Unit) and the serial port on SLC/ALC.
Setting a serial port on the CCU
Set each item as follows.
"Table A: Sensors that can be selected by serial ports on CCU" shows selectable sensors.
However, the sensors that actually can be selected vary depending on the equipment setting.
For the sensor communication speed, refer to "Selectable baud rates".
Tab name
display