Appendix C
Setting the Inter switch
C-2
C.1.2
Checking the connection status with the connected radar
antennas
The status of connection with the connected radar antenna is displayed by the Inter switch connection
change button of the Radar system information.
Note
Always a display unit that becomes the master is necessary for making a slave connection.
When putting a slave display unit in the transmit state, it is necessary to put the master display unit
in the transmit state.
The name of the connected radar antenna is displayed in the upper part.
The connection state is displayed in the lower part.
Memo
In simple Inter switch mode, only the connection status is displayed.
Connection state
[Master]: The state in which the display unit can control the radar antenna.
[Slave]: The control of the radar antenna is not possible.
In the [slave] state, transmit/stop, and pulse length change cannot be made. Also, there will be
restrictions on the usable range.
Inter switch connection change
button