Section 19 Adjusting and Setting up Equipment (for Services)
19-8
19.2.3.3 Setting a tuning bar peak value
Set the scale when the tuning bar touches the peak value.
Notes
• This function is disabled under radar slave mode.
• Not displayed when a solid-state radar antenna is connected.
• Disabled in ECDIS mode.
1
Set the range to 48 NM or more.
2
Click on the [Tune Indicator] (tune indicator bar display) input box.
A numeric value input keyboard is displayed.
3
Input a setting value in the input box so that the tuning bar oscillates within the range
from 80% to 90% of the maximum amplitude position (0 to 127).
For the method of using the numeric input keyboard, refer to "3.16.2 Name and function of each
section of the keyboard".
19.2.3.4 Adjusting a tuning peak value
Adjust a tuning indication and an echo peak.
Notes
• Disabled in radar slave mode.
• Displayed under 10kW radar (NKE-2103-6, NKE-2103-6HS) only.
1
Adjust the tuning indication bar as described in “19.2.3.3 Setting a tuning bar peak
value”.
2
Set the range to 48nm or more.
3
Click the [Tune Peak Adjustment] input box.
A numerical value input keyboard is displayed.
4
Adjust the tuning peak adjustment value so that the radar image becomes strongest
when the tuning indication at the top left corner of the screen points to the maximum.
For the method of using the numerical value input keyboard, refer to “3.16.2 Name and function
of each section of the keyboard”.
19.2.3.5 Setting bearing pulse output
Notes
Disabled in ECDIS mode.
1
From the [Output BP] (bearing pulse output) combo box, select a bearing pulse count
that is output from the radar antenna (2048 or 4096).