Symptom/Error Message
Possible Causes
Recovery Action
Reference paper is wrong.
Use the reference paper (KS-070)
for TAIKO.
CPU/Sensor board failure.
Replace the CPU/Sensor board.
See=> Chapter 6 Replacement
Procedure
Adjustment Error
5-2-2. Adjustment Troubles
Symptom/Error Message
Possible Causes
Recovery Action
Software does not match
with the currency.
Download the appropriate software
program to the TAIKO unit. See=>
4-1. Download
DIP Switch setting is wrong.
Set the accepting setting properly.
See=>
2-5. DIP Switch Setting
The command from Host is
set to inhibit.
Set the command to accept.
CPU/Sensor failure is
occurred.
Replace CPU/Sensor Board. See=>
Chapter 6 Replacement Procedure.
Sensor needs to be cleaned
and adjusted.
Clean all sensors. See=>
5-4.
Cleaning
Perform adjustment See=>4-2.
Adjustment
CPU board failure
Replace the CPU board. See=>
6-
2. Replacement of CPU board
DIP Switch setting is wrong.
Set the DIP Switch No.1 ON and
supply the power to the TAIKO unit.
DIP Switch is broken.
Perform the DIP Switch TEST.
See=>
5-3-2. DIP Switch Test
Details
If the test result is NG, replace the
CPU board. See=>
6-2. Replace of
CPU board
CPU board failure
Replace the CPU board. See=>
6-
2. Replace of CPU board
Cannot enter the Test Mode.
Motor rotates a few times
and stop.
All bills are returned.