caution
For your safety, when starting the heater, keep your
head and face away from the burner area opening
to prevent any risk of personal injury.
attention
Pour votre sécurité personnelle, lorsque vous
mettez l’appareil en marche, tenez votre tête et
votre visage loin du brûleur pour éviter tout risque
de blessure.
8. Make a visual check of the main burner flame.
The flame can be seen in a mirror arrangement
held beneath the burners. The flame should be:
a. Blue in color.
b. 1 to 4 inches (25mm to 102mm) above burner
surface. See Figure 26.
9. Perform a temperature rise test in accordance
with Section 7.8.
Section 9. troubleshooting
9.1
General Heater troubleshooting
Table 8 lists some of the more common
problems, causes and solutions encountered when
running the heater. Most problems occur when
the heater is being started for the first time after
installation or at spring start-up. Careful installation
and maintenance will help ensure years of trouble free
use from your Legacy heater.
9.2
Service codes
The Legacy Model LRZ electronic controller
monitors several functions of the heater. In the event
of a malfunction, the Legacy controller will display a
FAULT message. Table 9 lists the Legacy Model LRZ
electronic Heater Service Codes along with potential
causes and remedies.