Jandy® Legacy™ Model LRZE Pool/Spa Heater by Zodiac®
|
Installation and Operation Manual
Figure 15. Field Wiring connections
CONNECT WIRES
INSIDE HEATER
CONDUIT
ELBOW
WIRES AS
SHIPPED
Section 6. electrical
caution
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and
dangerous operation. Verify proper operation after
servicing.
caution
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and
dangerous operation. Verify proper operation after
servicing.
aVeRtiSSeMent
POSSIBILITÉ DE CHOCS ÉLECTRIQUES. Ce
système de chauffage contient du filage de haut
voltage. Un contact avec ces fils peut résulter en
des blessures sérieuses ou la mort.
WaRninG
eLectRicaL SHocK HaZaRd.
This heater
contains wiring that carries high voltage. Contact
with these wires may result in severe injury or
death.
6.1
General information
Wiring connections must be made exactly as
shown in the wiring diagram found on the inside of the
heater door, see Figure 16. The heater must include a
definite means of grounding. There is a bonding lug on
the right side of the heater, where a bond wire must be
attached.
6.2
Main Power
Electrical wiring must be in accordance with the
latest edition of the National Electric Code
®
(NEC),
ANSI/National Fire Protection Association (NFPA)
70, unless local code requirements indicate otherwise.
In Canada, the Canadian Electrical Code
®
(CEC, CSA
C22.1 No 1) must be followed.
The heater comes factory-wired intended for
use with 240 Volt, 60 Hz AC field electrical supply.
To use 120 Volt, 60 Hz AC requires rewiring of the
heater.
This must be done by a certified electrician
only, as with all wiring. To wire the heater for 120V,
60 Hz AC, follow the alternate 120V wiring method
depicted in Figure 16. Additionally, the ignition
control module must be rewired. The wire from the
terminal marked IGN/240 must be removed and placed
on the terminal marked IGN/120.
To wire the Legacy Model LRZ electronic heater
to a 120V or 240V /60 Hertz (Hz) electrical source:
1. Remove the door of the heater.
2. Connect the wires from the power source to the
leads on the right side of the heater in the space
behind the raceway. See Figure 15.
3. Connect a bonding wire (8ga copper) to the
bonding lug on the right side of the heater.