Page 25
ENGLISH
Installation and Operation Manual
|
Jandy® Legacy™ Model LRZE Pool/Spa Heater by Zodiac®
5. Restore power to the heater and the pool/spa
control system.
6.4.1.2 configure the control Panel
1. Make sure the control is in the
OFF
mode.
2. To enter the Service Setup mode, press and
hold the
MENU
,
POOL
, and
SPA
buttons for 5
seconds.
note
The display will revert back to OFF after one
minute since the last key press.
3. Press the Up or Down button to display
REMOTE
. Press the
MENU
button.The
SELECT REMOTE OFF
(default remote)
appears. Use the Up or Down button to scroll
through the Remote options. When you reach
HI-LO-COM
, press the
MENU
button to select
the remote. Press
POOL
or
SPA
to exit the
Service Setup mode.
6.4.2 connection to an aquaLink
®
RS, Pda, Remote tStat (2-
Wire connection) or Fireman's
Switch
6.4.2.1 install the Remote tStat
1. Turn off the power to both the pool/spa control
system and the heater unit.
2. Remove the front panel door from the front of the
heater to access the raceway.
3. Run the wires from the pool/spa control system
through the opening, located on the lower right or
left hand side of the heater.
4. Connect the wiring from the pool/spa control
system to the heater remote control terminal. See
Figure 18.
5. Restore power to the heater and the pool/spa
control system.
note
If you install a time clock to control the filter
pump operation, it is recommended that
the time clock have its own low voltage
(Fireman’s) switch to turn off the heater before
turning off the pump. The switch should shut
off the heater about 15 minutes before the
filter pump shuts off. This will allow for a more
efficient operation by removing any residual
heat contained in the heat exchanger back to
the pool.
6.4.2.2 configure the control Panel
1. Make sure the control is in the
OFF
mode.
2. To enter the Service Setup mode, press and
hold the
MENU
,
POOL
, and
SPA
buttons for 5
seconds.
note
The display will revert back to OFF after one
minute since the last key press.
3. Press the Up or Down button to display
REMOTE
. The
SELECT REMOTE OFF
(default remote) appears. Use the Up or Down
button to scroll through the Remote options.
When you reach
REMOTE TSTAT
, press the
MENU
button to select the remote. Press
POOL
or
SPA
to exit the Service Setup mode.
4. Press
SPA
. Adjust the setpoint to the maximum
setting of 104 °F.
6.4.3 connection to a Secondary
user interface
The Legacy Model LRZ electronic pool/spa
heater can also be controlled remotely by installing a
second wall mountable User Interface. Please order
Zodiac part number R0467500. This kit contains the
second User Interface, wall mounting backplate, and
necessary hardware.