Page 15
ENGLISH
Jandy
®
Pro Series TruClear
™
Chlorine Generating System
|
Installation & Operation Manual
5. Pass wires through center slot on bracket.
6. Use a small fl at head screwdriver to install the
wires from the automation system. Match the
colors to the wires already installed from the power
pack.
7. Once connection has been made, the User Interface
(UI) should display
“Standby ‡”.
8. Follow the instructions for your automation system
to continue with device set up and schedules.
9. Once proper communication is confi rmed, reinstall
the RS485 connector bracket into the
power pack body.
10. If proper communication is not established begin
with step 3 and retrace the above steps.
11. If communication is still not established please call
technical support at 800-822-7933.
NOTE
The TruClear does not capture a salinity reading from
your pool. When connected to an automation system,
the target salinity level of 3000ppm will be displayed.
"General Error" will show as a result of low salt, low temp
or a combination of both.
Use Copper Conductors Only
Rated for 90°C Minimum
Pool Pump
TO EARTH
BONDING POINT
POOL PUMP CONTROL
120 VAC
120 VAC
CIRCUIT BREAKER
PANEL
TO CELL
GROUND
NEUTRAL
LINE 1
BLK
GRN
LOAD 1 (BLK)
NEUTRAL
(WHITE)
GROUND (CHASSIS)
RED
VIOLET
WHITE
TO EARTH
BONDING POINT
ENGLISH
3
12
6
9
POWER PACK
Figure 6.
Wiring Diagram with a 120 VAC Filter Pump
Figure 7.
Wiring Diagram with a 240 VAC Filter Pump
Use Copper Conductors Only
Rated for 90°C Minimum
Pool Pump
TO EARTH
BONDING POINT
POOL PUMP CONTROL
240 VAC
CIRCUIT BREAKER
PANEL
TO CELL
GROUND
LINE 2
LINE 1
BLK
GRN
L 1 (BLK)
NOTE: VIOLET AND WHITE WIRES
ARE NOT USED FOR 240VAC WIRING
L 2 (RED)
GROUND (CHASSIS)
RED
VIOLET
WHITE
TO EARTH
BONDING POINT
ENGLISH
3
12
6
9
POWER PACK