3.2 Installation Requirements
WARNING
The Jandy Pro Series chlorine generating electrolytic
cell must be installed outdoors only. The cell must be
installed horizontally with the cord facing upwards to
avoid buildup of flammable gases which can result in
FIRE OR EXPLOSION.
The installation requirements for the Jandy Pro Series
chlorine generating device are as follows:
• Install the power pack at least 2 feet (0.6 m) above the
ground in order to protect it from pressurized water
spray such as that from irrigation sprinklers, and from
mechanical impacts and/or damage. Also ensure that
it is inaccessible to children. Consult and comply with
any and all applicable local and national installation
codes and/or regulations, as may be enforced by
the local Authorities Having Jurisdiction (AHJ’s) or
competent authority in Canada.
• In the U.S., the power pack must be installed at least
1.5 m (5 ft.) from the inside wall of your swimming
pool or spa; in Canada, the power pack must be
installed at least 3 m (10 ft.) from the inside wall of
your swimming pool or spa.
• The cell must be installed on a 0.4 m (16 in.)
horizontal length of pipe after the heaters, pumps,
and filters, as the last piece of equipment in the
circulation plumbing system. (see Figure 3).
• The cell must be installed no more than 4.6 m (15
ft.) from the power pack (see Figure 3).
• It is recommended that the cell be installed 25 cm
(10 in.) from any 90° elbow.
Section 3. Installation Instructions
WARNING
FOR YOUR SAFETY:
This product must be installed and serviced by a professional pool/spa service technician
as described on the front cover of this manual. The procedures in this manual must be followed exactly. Failure to
follow warning notices and instructions may result in property damage, serious injury, or death. Improper installation
and/or operation will void the warranty.
WARNING
EQUIPMENT UNDER PRESSURE:
Always turn pump off prior to installing or servicing the Jandy Pro Series
chlorine generating device. Your pump/filter system is operated under pressure and the pressure must be released
before you begin work. Please see your pump/filter owner’s manual for further instructions.
Disconnect power to the system at the main circuit breaker before performing this procedure to avoid risk of
electric shock which can result in property damage, severe injury or death.
Before you begin your installation, please check that
you have the right tools and a suitable location to install
the power pack and cell. Please ensure that you have
read and understood the Important Safety Instructions
section.
3.1 Materials and Tools
Tools and Materials Needed for Installation
• Screw Set (Plastic Anchors)
• Cordless Drill (or Power Drill)
• 6 mm (15/64 in.) Masonry Bit or Hammer Drill Bit
(only necessary to drill into brick or concrete)
• Pencil or Marking Pen
• Phillips Head Screwdriver or Phillips Head Drill Bit
• WELD-ON
®
724™ CPVC Gray Cement is
recommended
Figure 3.
Installation Requirements