Page 27
ENGLISH
Jandy
®
Pro Series TruClear
™
Chlorine Generating System
|
Installation & Operation Manual
Section 8. Display Readings
8.1 Display Reasons and Descriptions
Display Reading
Reason
Description
EN
Language on startup
This is the acronym which should appear
during the 3 seconds startup screen.
English
Language
Language selected/available for the user.
Output is OFF while selection is made.
Standby
Standby
When the system is ready and waiting for
the next valid chlorination cycle without any
errors. Output is OFF.
Standby ‡
Connected to Jandy Automation
When the system is connected to a
Jandy Automation System via RS485
communication cable and waiting for the next
valid chlorination cycle without any errors.
Output is OFF.
Chlorinating
Chlorination
When the system is operating within a valid
chlorination cycle without any errors. Output
is ON.
Cleaning
Polarity is reversing
When the system is operating within valid
chlorination cycle and the duty cycle timer
has expired. Output is OFF.
Lo Temp/Lo Salt
Low water conductivity
When the system detects low water
conductivity, this could be caused by cold
water, low salt levels, or a combination of the
two. Check the salt level. Output is ON.
No Flow
No flow or low flow
When the system detects an absence of flow
while operating within a valid chlorination
cycle. Output is OFF.
Check Cell
Cell overload
When the system is running within a valid
chlorination window and detects a cell short
circuit or overload. Designed to warn the
user or service person. Output is OFF.
Check Cell
Cell open circuit
When the system is running within a valid
chlorination window and detects a cell open circuit
or disconnection. Designed to warn the user or
service person. Output is off but retries each 30
seconds.
Over Temp
Overheated controller
The controller detects internal temperature and
may can reduce output power as a self-protection
feature.
At 70ºC (internal) output power to the cell is
reduced by 50% (no message displayed).
At 80º C (internal) output power to the cell is
reduced to 0% (OFF), and this over temperature
error is displayed. Output is OFF.
Designed to warn the user or service person of
overheating.
Please confirm that this warning message
automatically disappears when internal temp goes
below 80 °C.