12pin (DC IN/TRIG)
Input range︓ DC +10V 〜+ 25V
consumption︓ 8.0 W(typ.)
(at 12 V input, full pixel, Default setting, Environmental
temperature 25°C) (Typical)
12.4 W
(Maximum)
SFP+
10GBASE-R
Power level 1
12pin (DC IN/TRIG)
Model ︓ HR10A-10R-12PB(71) (or equivalent)
Function︓ Power supply input / External trigger / External I/O
10pin (AUX)
Model
Camera side︓Equivalaent to Hirose Electronic 3260-10S3 (55)
Cable side ︓Equivalaent to Hirose Electronic 350-10P-C (50)
Function︓ External tigger / External I/O
LED (Power/TRIG)
Function︓Power on, trigger input indicator
Weight
5℃〜+ 45℃ / 20%〜 80%
(non-condensing)
25℃〜+ 60℃ / 20%〜 80%
(non-condensing)
10G(20 Hz 〜 200 Hz X-Y-Z direction)
80G
CE(EN61000-6-2 and EN61000-6-3), FCC part 15 class B, RoHS, WEEE
62 × 62 × 102.3 mm (WHD; excluding mount and protrusions)
M42 mount : 340 g (typ.) F mount : 410 g (typ.)
Storage temperature / humidity
Operating temperature / humidity
Vibration resistance
Impact resistance
Dimensions
Flange back
M42 mount: 16 mm (in air), tolerance: 0 mm to –0.05 mm
F mount: 46.5 mm,
tolerance: 0 mm to –0.05 mm
Connectors / LEDs
Image porcessing
1 Pixel sensitivity correction: Pixel correction (DSNU, PRNU)
2 Shading correction: ColorShading, FlatShading
3 LUT: OFF: γ=1.0, ON: 257 points can be set
4 Gamma: 0.45, 0.5, 0.55, 0.6, 0.65, 0.75, 0.8, 0.9, 1.0 (9 steps available)
Power supply voltage
Lens mount
M42 mount, F mount
*) Maximum allowed rear protrusion on lenses: 13mm
Standard compliance
PRNU
DSNU
Post-correction: Within ±1% (during 100% output)
Post-correction: Within ±5% (during 0% output)
SW-4000TL-SFP
— 58 —
Package contentsCamera
body (1)
Sensor protection cap (1)
Dear Customer (sheet) (1)
Design and specifications are subject to change without notice.
Approximately 30 minutes of warm-up are required to achieve these specifications.
About the verified performance temperature
Make sure the following temperature conditions are met when operating the unit.
1) The camera's internal temperature sensor detects temperatures of 80 °C or less during
operation.
If the above temperature conditions are exceeded, take measures to dissipate heat according to
your installation environment and conditions.
Caution