Setting range
Default value
Description
Configure settings for encoder control.
Off,
Line4 (TTL In 1),
Line5 (Opt In 1),
Line10 (TTL In 2),
Line13 (TTL In 3)
Off
Select where to input the signal from the rotary encoder.
Off,
Line4 (TTL In 1),
Line5 (Opt In 1),
Line10 (TTL In 2),
Line13 (TTL In 3)
Off
Select where to input the signal from the rotary encoder.
1 〜 4294967295
65536
Set the number of triggers to be generated during one pitch of the rotary
encoder. The number of triggers is 65536 / (set value).
none, 2pulse,
4pulse, 8pulse,
16pulse, 32pulse
none
When the reliability of the interval of the signal output from the rotary
encoder is low.
(Some signal interval is extremely long or short).
When this function is enabled, internal processing is performed by averaging
the interval of several previous signals.
0 〜 150 (10 step)
0
Apply a low-pass filter to prevent noise on the signal from the rotary encoder
and stabilize the signal for the specified number of cycles.
1 〜 2550
10
Set the strobe length of the Trigger signal generated from the rotary encoder
by the number of cycles
Setting range
Default value
Description
Logic Block 0,
Logic Block 1
Logic Block 0
Specifies the Logic Block to configure.
Logic Block Function
AND
AND
Selects the combinational logic Function of the Logic Block to configure.
Logic Block Output Inverter
True
True
Selects if the selected Logic Block Output signal is inverted. (True fixed)
Logic Block Input Selector
0, 1
0
Selects the Logic Block's input to configure.
Logic Block Input Source
ー
Line4 (TTL In 1)
Selects the source signal for the input into the Logic Block.
[Setting range]
Exposure Active, LVAL,
Pulse Generator 0, Pulse Generator 1, Pulse Generator 2, Pulse Generator 3,
User Output 0, User Output 1, User Output 2, User Output 3,
Line4 (TTL In 1), Line5 (Opt IN 1), Line10 (TTL In 2), Line13 (TTL In 3),
Logic Block 0, Logic Block 1, Encoder Trigger
Logic Block Input Inverter
True, False
Selects if the selected Logic Block Input source signal is inverted.
Setting range
Default value
Description
Configure settings for action control.
0x00000000〜
0xFFFFFFFF
ー
An action command is executed if this ActionDeviceKey matches the
DeviceKey contained in the action command message.
ー
256 (Fixed)
Indicates the size of the scheduled action commands.
0,1,2,3
0
Select the ActionSelector.
Action Group Mask
0x00000000〜
0xFFFFFFFF
ー
An action command is executed if the result of an AND operation of
GroupMask contained in this ActionGroupMask and an action command
message is not 0.
Action Group Key
0x00000000〜
0xFFFFFFFF
ー
An action command is executed if this ActionGroupKey matches the
GroupKey contained in the action command message.
EncoderSourceA
EncoderDivider
Encoder Filter (ns)
EncoderStrobe (ns)
j) Logic Block Control
i) EncoderControl
Encoder Averaging Interval
EncoderSourceB
Action Device Key
Action Selector
Item
Item
Item
Logic Block Selector
Action Queue Size
k) Action Control
SW-4000TL-SFP
— 45 —