Setting range
Default value
Description
Configure settings for digital input/output.
Line1 (TTL Out 1),
Line4 (TTL In 1),
Line5 (Opt In 1),
Line8 (TTL Out 2),
Line9 (TTL Out 3),
Line10 (TTL In 2),
Line12 (TTL Out 4),
Line13 (TTL In 3)
ー
Select the input/output to configure.
Line Mode
Input, Output
ー
Display the input/output status
(whether it is input or output)
.
Line Inverter
True, False
False
Enable/disable polarity inversion for the selected input signal or output
signal.
Line Status
True, False
ー
Display the status of the input signal or output signal
(True: High, False: Low)
.
ー
ー
Display the input/output signal status. The state is shown with 16 bits. Bit
assignments are as follows.
bit0:Line1
bit3:Line4
bit4:Line5
bit7:Line8
bit8:Line9
bit9:Line10
bit11:Line12
bit12:Line13
bit1, bit2, bit5, bit6, bit10, bit13-31 unused (fixed 0)
ー
ー
Select the line source signal for the item selected in [Line Selector].
[Setting range]
Acquisition Active, Frame Active, Exposure Active,
LVAL, Pulse Generator 0, Pulse Generator 1, Pulse Generator 2, Pulse Generator 3,
User Output 0, User Output 1, User Output 2, User Output 3,
Line4 (TTL In 1), Line5 (Opt IN 1), Line10 (TTL In 2), Line13 (TTL In 3),
Logic Block 0, Logic Block 1, Encoder Trigger, Encoder Direction
TTL, OptoCoupled
ー
Display the signal format.
0 〜 1000000 step 100
Off
Remove noise from the OptIn input signal of Digital I/O.
UserOutput0, UserOutput1,
UserOutput2, UserOutput3
UserOutput0
Set the UserOutput signal.
UserOutputValue
True, False
False
Set the value for the UserOutput selected in [UserOutputSelector].
Red, Green, Blue
Red
Select the channel for exposure active.
Setting range
Default value
Description
Configure counter settings. (This camera only supports counter functions.)
Counter0, Counter1
Counter2, Counter3
Counter4, Counter5
ー
Select the counter.
Counter Event Source
ー
Off
Assign the counter event signal for which you want to read the count value
to a dedicated counter, and read the value.
[Setting range]
Counter0: Off, Line Trigger
Counter1: Off, Line Start
Counter2: Off, Exposure Start
Counter3: Off, Frame Trigger
Counter4: Off, Frame Start
Counter5: Off, Frame Transfer End
Counter Event Activation
ー
ー
Set the count timing.
The setting value is fixed with the following data.
Counter0 Rising Edge
Counter1 Rising Edge
Counter2 Rising Edge
Counter3 Rising Edge
Counter4 Rising Edge
Counter5 Falling Edge
Counter Reset
ー
ー
Reset the counter.
Counter Value
0〜65535
0
Display the count value.
Counter Status
ー
ー
Display the counter status.
Counter Idle: Idle
Counter Active: Counting
Counter Overflow: Count value exceeded the mazimum value.
ExposureActiveSource
UserOutputSelector
OptInFilterSelector (ns)
LineStatusAll
Line Selector
g) Digital I/O control
Item
Counter Selector
Line Source
Line Format
Item
h) Counter And Timer Control
SW-4000TL-SFP