Maximum frame rate period formula
During continuous operation ([Frame Start] trigger is [Off] or [Exposure Mode] is [Off])
• Maximum frame rate of sensor
FR_Cont = 1 / {H Period × ( 34)}
When the exposure time is longer than the frame interval
• Maximum exposure time at maximum frame rate
MaxExposureTime_TrOlrd = (1 / FR_Cont) - (14 × H Period)
• Exposure time outside of frame interval
NonOverlapExposureTime = ExposureTime - MaxExposureTime_TrOlrd
However, NonOverlapExposureTime calculation results that are 0 or below will be considered as 0.
• Maximum frame rate
FR_ContLongExposure = 1/{(1/FR_Cont) + NonOverlapExposureTime}
When [Frame Start] trigger is [On] and [Trigger OverLap] is [Off]
• Maximum frame rate of sensor
FR_Cont = 1 / {H Period × ( 34)}
• Maximum frame rate
FR_TrOloff = 1/{1/FR_Cont) + ExposureTime}
When [Frame Start] trigger is [On] and [Trigger OverLap] is [Readout]
• Maximum frame rate of sensor
FR_Cont = 1 / {H Period × ( 34)}
• Exposure time possible within frames
MaxOverlapTime_TrOlrd = (1 / FR_Cont) - (14 × H Period)
• Exposure time outside of frame interval
NonOverlapExposureTime_TrOlrd = ExposureTime - MaxOverlapTime_TrOlrd
However, NonOverlapExposureTime_TrOlrd calculation results that are 0 or below will be considered
as 0.
For TriggerWidth, the trigger pulse is equivalent to ExposureTime.
• Maximum frame rate
FR_TrOlrd = 1 / {(1 / FR_Cont) + NonOverlapExposureTime_TrOlrd}
Full size - Vertical Binning =1(OFF)
Tap Geometry
CL Pixel Clock (MHz)
H Period [usec]
Frame Rate (fps)
1X2-1Y
37.125
33.293
14.3
1X2-1Y
74.25
16.646
28.7
1X2-1Y
84.85
14.613
32.7
1X3-1Y
37.125
22.249
21.5
1X3-1Y
74.25
13.414
35.6
1X4-1Y
37.125
16.700
28.6
1X4-1Y
74.25
13.414
35.6