When Controlling the Exposure Time Using Specified Exposure Times
Configure the settings as follows.
Item
Setting value / selectable range
Trigger Selector (trigger operation)
Frame Start
Trigger Mode
On
Trigger Source (trigger signal source)
Any
Trigger Activation (trigger polarity)
Rising Edge (rising edge of input signal), Falling Edge (falling
edge of input signal)
Exposure Mode
Timed (control via exposure time)
Exposure Time
Varies depending on the Tap Geometry and CL Pixel Clock
settings.
Exposure Auto
Off, Continuous
1
Set [Exposure Mode] to [Timed].
([Timed] is the default setting.)
2
Specify the exposure time in [Exposure Time].
The setting value for the exposure time can only be changed when [Exposure Auto] is set to [Off].
If [Exposure Auto] is set to [Continuous], temporarily set it to [Off] before changing the exposure
time.
3
Set [Trigger Selector] to [Frame Start].
([Frame Start] is the default setting.)
4
Set [Trigger Mode] to [On].
5
If necessary, change the [Trigger Source], [Trigger Activation], and [Exposure Auto]
settings.
When Controlling the Exposure Time using the Pulse Width of the Trigger Input Signal
Configure the settings as follows.
Item
Setting value / selectable range
Trigger Selector (trigger operation)
Frame Start
Trigger Mode
On
Trigger Source (trigger signal source)
Any
Trigger Activation (trigger polarity)
Level High (high-level duration), Level Low (low-level
duration)
Exposure Mode
Trigger Width (control via trigger width)
1
Set [Exposure Mode] to [Trigger Width] .
When you select [Trigger Width], [Trigger Mode] will automatically be set to [On].
2
Set [Trigger Selector] to [Frame Start].
([Frame Start] is the default setting.)
3
If necessary, change the [Trigger Source] and [Trigger Activation] settings.