AM-800CL / AB-800CL
- 48 -
Command
Name
Format
Parameter
Remarks
LUTC?<CR><LF>
1=Gamma
2=LUT
2
Gamma
Selector
GAMS=[Param.]<CR><LF
>
GAMS?<CR><LF>
0 to 16
( Only Gamma)
3
LUT data
communication
for Red
LUTR=[Param.]<CR><LF>
LUTR?<CR><LF>
transfer by a serial method.
The number of the data is
512.
Param=0 to 8191
After sending
consecutive 512
data, LUT data can
be renewed
4
LUT data
communication
for Green
LUTG=[Param.]<CR><LF>
LUTG?<CR><LF>
transfer by a serial method.
The number of the data is
512.
Param=0 to 8191
After sending
consecutive 512
data, LUT data can
be renewed
5
LUT data
communication
for Blue
LUTB=[Param.]<CR><LF>
LUTB?<CR><LF>
transfer by a serial method.
The number of the data is
512.
Param=0 to 8191
After sending
consecutive 512
data, LUT data can
be renewed
J
– Gain and black level for TAP balance
1
Gain auto Tap
Balance
AWA=[Param.]<CR><LF>
0=OFF
1=Once(Run)
2=Continuous
2
Request the
Result of Gain
auto Tap
balance
WBRS?<CR><LF>
0=Complete.
1=Too Bright.
2=Too dark.
3=Timeout Error.
4=Busy.
5=Limit.
6= Trig is not set as
Normal.
3
Fine Gain for
Tap 2
GJUT2
=[Param.]<CR><LF
>
GJUT2?<CR><LF>
-891
~
1000
(Data+8192)/ 8192
±
1dB
for pixel Gain 1R
4
Fine Gain for
Tap 3
GJUT3
=[Param.]<CR><LF
>
GJUT3?<CR><LF>
-891
~
1000
(Data+8192)/ 8192
±
1dB
for pixel Gain 2L
5
Fine Gain for
Tap 4
GJUT4
=[Param.]<CR><LF
>
GJUT4?<CR><LF>
-891
~
1000
(Data+8192)/ 8192
±
1dB
for pixel Gain 2R
6
PixelGain RED
Tap2
PGR2=[Param.]<CR><LF>
PGR2?<CR><LF>
-891
~
1000
(Data+8192)/ 8192
±
1dB
(Only AB-800CL)
Pixel Gain for Tap2
7
Pixel Gain Blue
Tap2
PGB2=[Param.]<CR><LF>
PGB2?<CR><LF>
-891
~
1000
(Data+8192)/ 8192
(Only AB-800CL)
Pixel Gain for Tap2