AM-800CL / AB-800CL
- 29 -
7.2.1 Mode
The AM-800CL and AB-800CLhave the following exposure modes.
1.
EM=0
OFF
2.
EM=1
Timed
3.
EM=2
Trigger width
7.2.2 Exposure time setting (Command: PE)
PE command can be set if EM (Exposure mode) is set at 1 or 2.
Minimum exposure
time
~
Maximum
exposure
time
Full pixels
10
μ
s
~
2 sec(Note)
Binning
(
HxV
)
1 x 2
2 x 1
2 x 2
Note: The AM-800CL and AB-800CL are designed so that frame rate has priority over
exposure time. Accordingly, if the exposure time is set at a longer accumulation time than
1 frame (58.7326ms), the frame rate should be set at a longer time than the exposure time.
7.2.3 Exposure sequence (Commands EXSQ,PES(N), PER(N), EXSR, EXSEP, PE1
~
PE16)
Up to 16 exposure settings can be preset as a sequence. Each setting can also be repeated.
This function is effective only when the trigger mode is ON, the exposure mode is set to
Timed and the exposure sequence is ON.
7.3. Trigger Control
7.3.1 Selection of the trigger input(Command: TI)
The command “TI” can select the trigger input. At TI=0, the input through Camera Link
(line 0) is active and at TI=1, the input through the Hirose 12-pin connector is active. The
factory default setting is the Camera Link input.
7.3.2 Trigger activation(Command: TA)
The command
“
TA
”
can select how to activate the trigger.
TA=0
Rising edge
At the rising edge of the pulse, the accumulation and the
readout will start.
TA=1
Falling edge
At the falling edge of the pulse, the accumulation and the
readout will start.
TA=2 High
During the high level of trigger, the accumulation is activated
and at the low level, the read out is activated.
TA=3 Low
During the low level of trigger, the accumulation is activated
and at the hight level, the read out is activated.