background image

V03 

JCAII  

CONTENTS 

1. Introduction ........................................................................................................... 1

 

2. Precautions ........................................................................................................... 1

 

3. Before Using the Product..................................................................................... 1

 

3-1 Unpacking and Checking......................................................................................................... 1

 

3-2 Installing Components ............................................................................................................. 1

 

3-3 Leveling the Scale .................................................................................................................... 1

 

4. Product Introduction ............................................................................................ 2

 

4-1 Display....................................................................................................................................... 2

 

4-2 Keypad ...................................................................................................................................... 3

 

5. Analog Section...................................................................................................... 4

 

6. Setting mode ......................................................................................................... 4

 

7. Dual Channel ......................................................................................................... 5

 

7-1 Diagram of sub channel connector......................................................................................... 5

 

7-2 Installation Process.................................................................................................................. 5

 

7-3 Setup ......................................................................................................................................... 6

 

7-4 Maximum Capacity & Division Setting & Unit ........................................................................ 6

 

7-5 Calibration................................................................................................................................. 7

 

7-6 Set AD gain of remote platform ............................................................................................... 8

 

7-7 Switch between Main scale and Remote platform................................................................. 8

 

8. Operation ............................................................................................................... 8

 

8-1 Zero-point.................................................................................................................................. 8

 

8-2 Tare & Preset Tare .................................................................................................................... 9

 

8-2-1 Tare .................................................................................................................................. 9

 

8-2-2Preset Tare........................................................................................................................ 9

 

8-2-3 Auto-tare .......................................................................................................................... 9

 

8-3 Counting method.................................................................................................................... 10

 

8-3-1Key in a known unit value ............................................................................................... 10

 

8-3-2 Sample counting ............................................................................................................ 10

 

8-3-3 ACAI................................................................................................................................11

 

8-3-4  Simple Recipe Function ……………………………………………………..……………….11 

8-4 Accumulation.......................................................................................................................... 12

 

8-4-1 Choose Accumulation Mode .......................................................................................... 12

 

8-4-2 Set the Max Account of accumulation ............................................................................ 12

 

8-4-3 Manual Accumulation ..................................................................................................... 12

 

8-4-4 Accumulation display...................................................................................................... 13

 

8-4-5 Print while display of accumulation ................................................................................ 13

 

8-4-6 Delete accumulation....................................................................................................... 13

 

8-5 Print ......................................................................................................................................... 14

 

Summary of Contents for JCAII

Page 1: ...it 6 7 5 Calibration 7 7 6 Set AD gain of remote platform 8 7 7 Switch between Main scale and Remote platform 8 8 Operation 8 8 1 Zero point 8 8 2 Tare Preset Tare 9 8 2 1 Tare 9 8 2 2Preset Tare 9 8 2 3 Auto tare 9 8 3 Counting method 10 8 3 1Key in a known unit value 10 8 3 2 Sample counting 10 8 3 3 ACAI 11 8 3 4 Simple Recipe Function 11 8 4 Accumulation 12 8 4 1 Choose Accumulation Mode 12 8 ...

Page 2: ...it of quantity 18 8 7 2 Set the low limit of quantity 18 8 7 3 Enable Disable the quantity check function 18 8 8 Weight check 18 8 8 1Set the high limit of weight 18 8 8 2Set the low limit of weight 19 8 8 3Enable Disable the weight check function 19 8 9 Unit weight ID 19 8 9 1Saving ID method 1 19 8 9 2Saving ID method 2 20 8 9 3Call up ID 20 8 10Label 20 8 11Time Setting 21 8 12 Error message 21...

Page 3: ...rformed by authorized personnel only 3 Before Using the Product 3 1 Unpacking and Checking Open the package and check the instrument for transport damage Immediately inform your dealer if you have complaints or if parts are missing The package should contain Scale body User manual Stainless steel pan Wire power cord 3 2 Installing Components Cover the stainless steel pan on the top housing properl...

Page 4: ...lue entered via numeric keys 7 Under the sample counting mode Symbol points at SMPL when calculated unit weight is lower than 4 5 of scale division or the quantity of sample is less than 10 pieces 8 Accumulation function is enabled under weighing mode 9 Under entering a known unit weight mode Symbol points at UW when entered unit weight is lower than 4 5 of scale division Unit weight is too small ...

Page 5: ...ntries Key can be also as a space key when edit label Decimal point Initiates function setting Sets the weight to zero Clears the indicated input values Displays gross and net weight by turns Inputs unit weight and run its counting function Enters the sampling mode and change its scale choice scale 1 or 2 Switches between main scale and remote platform Adds the indicated weight or piece count valu...

Page 6: ...weighing Call up unit weight ID Enable switch on relay output function under HI LO setting Print Disable switch off relay output function under HI LO setting 5 Analog Section Input sensitivity 1 4mV V Zero adj Range 20 FS A D conversion rate 10 times per second Load cell excitation 5V DC Number of load cells up to 4x350 ohm loadcells Resolution 1 30 000 6 Setting mode 1 Under the weighing mode lon...

Page 7: ...isplay when price is zero 4 P 03 Beep sound default in when check is OK when check is Hi Lo using scale s buzzer when check is OK when check is Hi Lo using light tower s buzzer 5 P 04 ACAI default off Options off 5 10 15 20 25 30 35 40 45 6 P 05 Printer model default normal Options normal EZ BP SH ZEBRA normal as compatible printer 7 P 06 Rs 232 Baud Rate default 9600 Options 19200 9600 4800 2400 ...

Page 8: ... only Use the main scale only 5 Press key to save the setting and return to weighing mode 7 4 Maximum Capacity Division Setting Unit 1 Press and hold while turning on the scale Do not release till is displayed in the Total Count window 2 Use numeric keys together with to input the new capacity press key to clears the indicated input values 3 Press key advance to division setting Use numeric keys t...

Page 9: ...apacity and division of the remote platform Here take JCAII 6K as an example 1 Press key and hold while turning on the scale Do not release till is displayed in the Unit Weight window 2 With no load on the weighing pan press key to start the zero point calibration and wait till is displayed in the Unit Weight window Input the first calibration weight value by the numeric key 6K model 1 3 of full l...

Page 10: ...ons 1 2 4 8 16 32 64 5 Press to save and return to normal weighing mode 7 7 Switch between Main scale and Remote platform 1 Press to switch between main scale mode and sub channel mode remote platform 2 The flashed in the Weight Window 3 When flashing disappear means that you are in the sub channel mode remote platform Now the remote platform could be used 4 To change back to the main scale mode j...

Page 11: ... together with key and press to switch units g kg scale will beep if the tare value is larger than full capacity 2 Press key The symbol appears with a symbol pointing at NET and another pointing at PRESET TARE 3 Put the load on the container The display shown is the Net weight Press key to see the gross weight 4 To clear tare with an empty pan press key 8 2 3 Auto tare Set the high limit of the ta...

Page 12: ... unit of normal weighing and tare setting are same 8 3 Counting method 8 3 1Key in a known unit value 1 Use numeric key to input the unit weight value eg 1 2g then press key 2 Put the article on the pan and the scale starts counting Note Symbol points at UW when entered unit weight is lower than 4 5 of scale division Unit weight is too small for ensuring accurate quantity calculations 8 3 2 Sample...

Page 13: ...s than previous reference weight Once the limit is exceeded ACAI is turned off Note z If you set the average parameter P4 to OFF it means that the scale will do the ACAI in all situations z If you set the average parameter to 15 the scale will not work if there is an object shortage or more than 15 of the unit weight z Whether it works or not depends on the object s tolerant of weight 8 3 4 Simple...

Page 14: ...display is blinking 2 Press to save and return And now you can accumulate up to 9 times only Note You can change the max accumulation back to 99 times by repeating the above steps It will beep for 3 seconds when accumulate to the max account eg Max accumulation 9 and the is blinking Under this condition you have the following options z Press it will print every set and total is still blinking It i...

Page 15: ...e 4 Skip 2 3 steps and press any numeric key to see a certain accumulation For example if you want to see the 12th accumulation press key 5 Press to return to normal weighing mode 8 4 5 Print while display of accumulation Note Only for SH 24 Print a certain accumulation Enter a certain accumulation display press Print total accumulation Enter total accumulation display press Weight on the scale wi...

Page 16: ... mode 8 5 Print Put the load on the pan and press key to print Note the weight should be more than 20e 8 5 1 Set a Print form EZ BP GP set 0 99 forms The printer should be initialized first SH 24 set 0 15 forms 1 Press key with no load on the pan 2 Key in the Form Number with numeric key For example if you want to choose the 9th form press 3 Press key to complete and return to weighing mode Sample...

Page 17: ...PC Please email us and we will make the requested print form for you Note for Prt 02 we suggest to use large label with the width of 100mm as the bar code is longer Samples of SH 24 Print Forms When appear under display of accumulation press the printout will be as following Prt08 15 print forms with unit weight Prt08 15 print forms with tare weight ...

Page 18: ...wn is 3 Press key or to choose the print mode Manual Print after appears Print when quantity is ok with check function Print when weight is ok with check function Print continuously No action 4 Press key to complete and return to weighing mode 8 5 3 Select the Printer Model 1 Under normal weighing mode keep pressing for about three seconds to enter parameter setting 2 Press or to switch between th...

Page 19: ... return 8 6 2 Set Max Serial Number The max serial number is 9999 but you can change the max serial number as shown below For example if you want to change the max serial number to 9 do as the following 1 Press and the Unit Weight display is blinking 2 Press to save and return Note When the serial number reaches the max the Unit Weight display will flash and beep for 3 seconds and then return to n...

Page 20: ... while the arrow is pointing at LO If the value in Total Count window is not blinking press Eg 111pieces 2 Use numeric key to input the low limit of quantity you want 3 Press to save and return 8 7 3 Enable Disable the quantity check function 1 Under normal weighing mode press or The display in the Total Count window is blinking If the value in Total Count window is not blinking press 2 If you wan...

Page 21: ...inking press E g 2kg 2 Use numeric key to input the low limit of weight you want 3 Press to save and return 8 8 3Enable Disable the weight check function 1 Under normal weighing mode press or The display in the Weight window is blinking If the value in Weight window is not blinking press 2 If you want to enable the function press If you want to disable the function press Note When the HI LO checki...

Page 22: ...12 1 Press and key in the accumulation number and the Total Count window will blinking 3 Press to save 8 9 3Call up ID Note If the Unit Weight display is not showing 0 please press first 1 under normal weighing mode press 2 Use numeric key to input a certain ID e g to call up ID 13 3 Press to confirm and the scale is ready for counting 8 10Label Set your own label Note The label can save up to 32 ...

Page 23: ... is Arrow pointing at LO means that the last 16 characters can be edited 6 Do as steps 2 4 7 Press to save and return to normal weighing mode 8 11Time Setting 1 Press and hold under normal weighing mode 2 Press to enter adjusting mode 3 Press to move leftwards and to move rightwards Use numeric key to input the adjustment 4 Press to save and return 8 12 Error message Error Message Reasons Solution...

Page 24: ...eighing mode 2 Change another bigger unit weight The last accumulation is more than the preset accumulation allowed Press key twice to clear the all the accumulation or press key to return to normal weighing mode 8 13 Problem Solution Printer cannot print out z Make sure the parameter P 05 is set correctly z Make sure the parameter P 06 and P 07 match the printer z If EZ or BP is being used they s...

Page 25: ...TDP printer Scale to SH 24 TP printer Universal 9 pin male to 9 pin male RS 232 connecting cable Universal 9 pin male to 25 pin male RS 232 connecting cable Scale to ZEBRA printer Scale to EZ printer Universal 9 pin male to 9 pin male RS 232 connecting cable Universal 9 pin male to 9 pin male RS 232 connecting cable Scale to PC 1 Connect the scale and computer by using the RS232 cable as the follo...

Page 26: ...ata When Print Mode Set As Continue Case1 No unit weight on Scale header1 header2 weight unit 8digits Case2 with unit weight on Scale header1 header2 weight unit unit weight unit piece 8digits 6digits 6digits header1 ST STABLE US UNSTABLE header2 NT NET GS GROSS examples for Case1 ST NT 12 350 kg US GS 30 000 lb examples for Case2 ST NT 10 000 kg 1 0000 g 10000 PCS US GS 30 000 l b 0 0010 l b 3000...

Page 27: ... 46 38 G W 1 000kg U W 0 5g Total 400PCS AP3 EZ godex AP4 SH 24 Can print out accumulation data AP5 LED Display Only the weighing data can be shown on the LED display AP6 Light tower can indicate three different situation LED Light Tower ...

Page 28: ...V03 JCAII 26 Two optional devices being used Option Application AP1 BP Or ZEBRA Or GODEX Or LED Light Tower Or PC LED Display ...

Page 29: ...V03 JCAII 27 AP2 BP Or ZEBRA Or GODEX Or PC Three optional devices being used ...

Page 30: ...V03 JCAII 28 Option Application AP1 BP Or ZEBRA Or GODEX Or PC LED Display And LED Light Tower 10 Relay Module Diagram RELAY OUTPUT Alarm COM N C N O ...

Page 31: ...V03 JCAII 29 HI COM N C N O OK COM N C N O LO COM N C N O RELAY CONTACT SPEC 1A 24VDC 0 5A 125VAC 0 25A 250VDC ...

Reviews: