![background image](http://html1.mh-extra.com/html/jacuzzi/profile/profile_instructions-for-preinstallation_3596400015.webp)
15
and the distances, the chosen protection systems and
the specific regulations for fixed electrical systems in
force in the country where the spa is installed. The elec-
trical box terminal board is designed for cables with sec-
tions up to 6 mm
2
.
I
To ensure the degree of protection against splashes of water
as required by standards, and to make connection to the elec-
trical mains easier, the electrical box is equipped with a cable
clamp M32 x 1.5mm.
I
The installer must comply with the above regulations, and al-
so
use watertight connectors at connection points. He
must also guarantee compliance with the specific current
standards for systems in the country in which the spa is
installed.
It is mandatory to comply with this instruction. Any oth-
er procedure is prohibited.
Electrical safety
Profile is a safe appliance, manufactured according to
E N
60335.2.60, EN 61000, EN 55014
regulations and tested dur-
ing production to guarantee user safety.
I
Installation must be carried out by qualified and authorized per-
sonnel, in compliance with current national provisions.
It is the responsibility of the installer to select ma-
terials based on their intended use, to carry out
work properly, to check the condition of the system
that the unit will be connected to and that it en-
sures safety of use, also concerning maintenance
work and the possibility to examine the system.
I
The Jacuzzi
®
spas are class
“I”
appliances and therefore they
must be permanently connected,
without any intermediate
connections
, to the electrical system and to the protection sys-
tem (earth system).
The electrical system of the building must be pro-
vided with a 0.03A differential switch and with an ef-
ficient protection (earth) circuit.
Check for proper operation of the differential switch
by pressing the TEST button, which should trip.
몇
Parts incorporating electrical components, except
remote control devices, must be located or fixed so
that they cannot fall into the spa.
Live components and equipment must be out of
reach of individuals in the spa.
I
For electrical connections, the installation of a multiple-pole
section switch is compulsory (
i
4
). It must be positioned in a
place that complies with safety regulations and, in any case,
which cannot be reached by those using the spa.
It is mandatory to comply with this instruction. Any oth-
er procedure is prohibited.
몇
If the building’s electrical system is not able to gua-
rantee a stabile power supply, it is recommended to
install a voltage stabiliser that suitably dimensio-
ned for the required power upstream of the equip-
ment.
I
The disconnection devices must be installed in the power supply net-
work according to the installation instructions.
I
The installation of electrical devices and equipment (sockets,
switches, etc.) near the spa must be in compliance with legal s-
tandards and regulations in the country where the spa is in-
stalled.
I
For the equipotential connection as required by specific na-
tional standards, the installer must use the terminal provided (s-
tandard
EN 60335.2.60
) under the electrical box (
i
4
), and
marked with the symbol
.
In particular, an equipotential con-
dition must be established for all metallic masses surrounding the
spa, for example water and gas pipes, metallic platforms, and so
on.
I
The appliance comes equipped with an LED lighting system, in com-
pliance with Regulation
EN 62471:2009.
CAUTION! Before carrying out any maintenance opera-
tion, disconnect the appliance from the power supply line.