conMIG 400/445/545
Operating manual
Page 29
22. Technical data
Power source
conMIG 400
conMIG 445
conMIG 545
Supply voltage, 50 Hz
400 V, 3 Phase, +/- 10%
400 V, 3 Phase, +/- 10%
400 V, 3 Phase, +/- 10%
Current consumption
Imax = 32 A, Ieff = 25A
Imax = 35 A, Ieff = 27A
Imax = 52 A, Ieff = 40A
Fuse
32 A slow
32 A slow
50 A slow
Max. power draw
22 kVA
24,5 kVA
36,5 kVA
Set point range
50 - 400 A
50 - 450 A
50 - 550 A
Operating voltage
16,5 – 34 V
16,5 – 36,5 V
16,5 – 41,5 V
Open-circuit voltage
20 – 52 V
20 – 57 V
20 – 66 V
Duty cycle 60 % (40°C)
400 A / 34 V
450 A / 36,5 V
550 A / 41,5 V
Duty cycle 100 % (40°C)
350 A / 31,5 V
400 A / 34 V
450 A / 36,5 V
System of protection
IP 23
IP 23
IP 23
Insulating category
H (180° C)
H (180° C)
H (180° C)
System of cooling
F
F
F
Weight (solo)
186 kg
238 kg
230 kg
Dimens. L x B x H (mm)
1070 x 490 x 945
1100 x 500 x 1000
1100 x 500 x 1000
Noise emission
< 70 dB(A)
< 70 dB(A)
< 70 dB(A)
Wire feed
DVK 3
DVK 4
Wire feed motor
42 V, 100 W
42 V, 140 W
Wire feed speed
0,8 - 24 m/min
0,8 - 24 m/min
Diameter of wire
0,8 - 1,6 mm
0,8 - 1,6 mm
Weight (solo)
20 kg
28 kg
Dimens. L x B x H (mm)
580 x 270 x 560
650 x 450 x 360
Authorized for welding under increased electrical hazard
Manufactured in accordance with EN 60 974-1 and EN 60 974-10
Generator operation:
The generator must have 30% more power as the welding unit.
Example: 22kVA (unit) + 30% = 30kVA. The generator for this unit must have 30kVA.
A generator with less power will damage the Jäckle welding unit as well as the generator himself
and is disallowed.
23. Environmental conditions
The power source must be operated at a temperature between -10°C to +40°C and a relative humidity of 50% at
40°C or up to 90% at +20°C. The ambient air must be free of unusual amounts of dust, acids, corrosive gases
or substances, etc., unless they occur during welding.
To prevent damage to the machine the temperature around the machine is controlled.
If this temperature is below -10°C or above + 40°C, the following text appear on the display and the machine
can not be started:
t°C - int – ‚measured temperature value’
Only when the temperature is in the prescribed range, the welding operation can be started.
Summary of Contents for conMIG 400
Page 2: ......
Page 28: ...conMIG 400 445 545 Operating manual Page 25...
Page 54: ...conMIG 400 445 545 Operating manual Page 51 Seitenansicht links sideview left...
Page 56: ...conMIG 400 445 545 Operating manual Page 53 Seitenansicht rechts sideview right...
Page 58: ...conMIG 400 445 545 Operating manual Page 55 Koffer wire feed case DVK 3 2010...
Page 61: ...conMIG 400 445 545 Operating manual Page 58 Koffer wire feed case DVK 4 2010...
Page 71: ......